Smart Footwear Estimates Capillary Refill Time for Peripheral Perfusion Monitoring
Posted on 24 Nov 2026
Peripheral perfusion reflects how effectively blood reaches the body’s extremities and is commonly assessed in hospitals by measuring capillary refill time. However, repeated monitoring during daily activities is challenging because conventional measurements require manual pressure and visual observation, making continuous assessment of blood flow to the feet impractical outside clinical settings. To overcome this limitation, researchers have developed smart footwear that uses ordinary walking to enable repeated monitoring of peripheral perfusion.
Researchers at Pohang University of Science and Technology (POSTECH; Pohang, South Korea) have developed CapWear, a smart footwear system designed to estimate plantar capillary refill time during everyday walking. The findings were presented at the 2026 ACM International Symposium on Wearable Computers (ISWC 2026) and published in the conference proceedings.
CapWear uses the natural pressure applied and released by the foot during walking to replicate the process used in conventional capillary refill assessments. A compact optical module positioned beneath the heel incorporates a light source, miniature camera, and pressure sensor. The pressure sensor detects when the foot contacts and lifts off the ground, while the optical system captures subtle changes in heel skin color as blood returns following pressure release.
Because the foot quickly returns to the ground during walking, the system has approximately one second to capture blood flow recovery with each step. To overcome this limitation, the researchers conducted separate measurement sessions in which the full recovery process could be observed. These measurements provided reference capillary refill time values used to train personalized models that account for individual differences in skin characteristics and blood flow.
To evaluate the system's accuracy, the researchers compared CapWear's estimates with reference capillary refill times obtained through manual review of heel videos by an emergency medicine physician. The results showed a strong positive correlation between the system's estimates and clinician measurements, with a correlation coefficient of 0.71, supporting its potential for monitoring peripheral perfusion during everyday activities.
“This study demonstrates the potential to measure capillary refill time naturally and repeatedly during walking, without requiring a separate measurement procedure,” said Professor Inseok Hwang of the Department of Computer Science and Engineering at POSTECH.
“We hope to develop this approach into a health care technology that can unobtrusively and continuously track changes in peripheral perfusion associated with various diseases and health conditions during everyday life,” added Hwang.
Related Links
POSTECH