Total Wrist Replacement Device Treats Painful Arthritis
|
By HospiMedica International staff writers Posted on 08 Apr 2020 |

Image: The KinematX modular wrist arthoplasty system (Photo courtesy of Extremity Medical)
A novel total wrist implant mimics the kinematics of a human wrist, enabling it to be more durable than traditional replacement options.
The Extremity Medical (Parsippany, NJ, USA) KinematX modular wrist arthoplasty system is designed to serve as a replacement for wrist joints disabled by pain, deformity, and limited motion, caused by non-inflammatory degenerative joint disease of the radiocarpal joint, such as osteoarthritis (OA), rheumatoid arthritis (RA), post-traumatic arthritis, Kienbock’s disease, revisions, and scapholunate advanced collapse (SLAC). The device is designed to create an anatomic coupling of radial extension, ulnar flexion and radio-ulnar deviation, similar to that of an intact wrist.
The system includes left and right specific radial body implants in three size options and two heights, with features that include an anatomic design to emulate the proximal row; a chrome-cobalt stem with titanium plasma spray coating; allowance for midcarpal articulation; preservation of radial length and inclination-stable radial fixation; a streamlined implantation technique that removes the risk of distal hardware loosening; and provision for future conversion to a total wrist arthroplasty. An X-ray template determines the anticipated prosthesis size, and implant trial sets are available for intraoperative trialing.
“We believe the new wrist replacement, known as the KinematX Total Wrist Implant, has advantages over traditional implants, which often constrain the wrist to move in one plane at a time, and this puts stress on surrounding joints,” said hand surgeon Scott Wolfe, MD, of the Hospital for Special Surgery (HSS; New York, NY, USA), who developed KinematX together with Joseph Crisco, III, PhD, director of the Bioengineering Laboratory at Brown University (Providence, RI, USA). “Our extensive research into how the wrist moves helped us design a replacement that more closely matches the anatomy and motion of a normal wrist. This should allow for more natural motion and increased durability compared to currently available implants.”
Wrist arthritis is one of the most common and debilitating conditions treated by hand surgeons. The human wrist is highly complex, made up of more than a dozen individual joints formed by eight small bones. Fusion of the wrist bones can alleviate pain, but patients are often limited in performing some activities. By enabling the radius and the ulna bone to move with respect to each other, the natural range of wrist rotation can be preserved, improving performance of activities of daily living and reducing compensatory movements.
Related Links:
Extremity Medical
The Extremity Medical (Parsippany, NJ, USA) KinematX modular wrist arthoplasty system is designed to serve as a replacement for wrist joints disabled by pain, deformity, and limited motion, caused by non-inflammatory degenerative joint disease of the radiocarpal joint, such as osteoarthritis (OA), rheumatoid arthritis (RA), post-traumatic arthritis, Kienbock’s disease, revisions, and scapholunate advanced collapse (SLAC). The device is designed to create an anatomic coupling of radial extension, ulnar flexion and radio-ulnar deviation, similar to that of an intact wrist.
The system includes left and right specific radial body implants in three size options and two heights, with features that include an anatomic design to emulate the proximal row; a chrome-cobalt stem with titanium plasma spray coating; allowance for midcarpal articulation; preservation of radial length and inclination-stable radial fixation; a streamlined implantation technique that removes the risk of distal hardware loosening; and provision for future conversion to a total wrist arthroplasty. An X-ray template determines the anticipated prosthesis size, and implant trial sets are available for intraoperative trialing.
“We believe the new wrist replacement, known as the KinematX Total Wrist Implant, has advantages over traditional implants, which often constrain the wrist to move in one plane at a time, and this puts stress on surrounding joints,” said hand surgeon Scott Wolfe, MD, of the Hospital for Special Surgery (HSS; New York, NY, USA), who developed KinematX together with Joseph Crisco, III, PhD, director of the Bioengineering Laboratory at Brown University (Providence, RI, USA). “Our extensive research into how the wrist moves helped us design a replacement that more closely matches the anatomy and motion of a normal wrist. This should allow for more natural motion and increased durability compared to currently available implants.”
Wrist arthritis is one of the most common and debilitating conditions treated by hand surgeons. The human wrist is highly complex, made up of more than a dozen individual joints formed by eight small bones. Fusion of the wrist bones can alleviate pain, but patients are often limited in performing some activities. By enabling the radius and the ulna bone to move with respect to each other, the natural range of wrist rotation can be preserved, improving performance of activities of daily living and reducing compensatory movements.
Related Links:
Extremity Medical
Latest Surgical Techniques News
- Continuous Monitoring with Wearables Enhances Postoperative Patient Safety
- New Approach Enables Customized Muscle Tissue Without Biomaterial Scaffolds
- Robot-Assisted Brain Angiography Improves Procedural Outcomes
- Brain Mapping Technology Enhances Precision in Brain Tumor Resection
- Handheld Robotic System Expands Options for Total Knee Surgery
- VR Experience Reduces Patient Anxiety Before Kidney Stone Procedure
- Injectable Mini Livers Offer Hope for Patients Awaiting Transplant
- Pulsed Field Ablation Technology Cleared in Europe for Persistent AFib
- AI-Powered Imaging Brings Real-Time Margin Clarity to Breast Cancer Surgery
- Minimally Invasive Device Safely Treats Challenging Brain Aneurysms
- Surgical Robot Makes Complex Liver Tumor Surgery Safer and Less Invasive
- Neurostimulation Implant Reduces Seizure Burden in Drug-Resistant Epilepsy
- Minimally Invasive Procedure Effectively Treats Small Kidney Cancers
- Fluorescence Probe Paired with Engineered Enzymes Lights Up Tumors for Easier Surgical Removal
- Novel Hydrogel Could Become Bone Implant of the Future
- Skull Implant Design Could Shape Surgical Outcomes
Channels
Artificial Intelligence
view channel
Machine Learning Approach Enhances Liver Cancer Risk Stratification
Hepatocellular carcinoma, the most common form of primary liver cancer, is often detected late despite targeted surveillance programs. Current screening guidelines emphasize patients with known cirrhosis,... Read more
New AI Approach Monitors Brain Health Using Passive Wearable Data
Brain health spans cognitive and emotional functions and can fluctuate even in adults without diagnosed disease. Detecting early changes remains difficult in routine care and burdens specialty services... Read moreCritical Care
view channel
Automated IV Labeling Solution Improves Infusion Safety and Efficiency
Medication administration in high-acuity settings is often complicated by multiple concurrent infusions, making accurate line identification essential. In a 10-hospital intensive care unit study, 60% of... Read more
First-Of-Its-Kind AI Tool Detects Pulmonary Hypertension from Standard ECGs
Pulmonary hypertension is a progressive, life‑threatening disease that is frequently missed early because symptoms such as dyspnea are nonspecific and diagnostic delays can exceed two years.... Read morePatient Care
view channel
Wearable Sleep Data Predict Adherence to Pulmonary Rehabilitation
Chronic obstructive pulmonary disease (COPD) is a long-term lung disorder that makes breathing difficult and often disturbs sleep, reducing energy for daily activities. Limited engagement in pulmonary... Read more
Revolutionary Automatic IV-Line Flushing Device to Enhance Infusion Care
More than 80% of in-hospital patients receive intravenous (IV) therapy. Every dose of IV medicine delivered in a small volume (<250 mL) infusion bag should be followed by subsequent flushing to ensure... Read moreHealth IT
view channel
EMR-Based Tool Predicts Graft Failure After Kidney Transplant
Kidney transplantation offers patients with end-stage kidney disease longer survival and better quality of life than dialysis, yet graft failure remains a major challenge. Although a successful transplant... Read more
Printable Molecule-Selective Nanoparticles Enable Mass Production of Wearable Biosensors
The future of medicine is likely to focus on the personalization of healthcare—understanding exactly what an individual requires and delivering the appropriate combination of nutrients, metabolites, and... Read moreBusiness
view channel







