Portable Sensor Detects Blood Ammonia Levels
|
By HospiMedica International staff writers Posted on 05 Aug 2020 |

Image: A handheld gas-phase based sensor measures ammonia levels in blood (Photo courtesy of Stanford University)
A new study reports how a gas-phase based sensor can measure ammonia levels from small-volume whole blood samples in minutes.
Developed by researchers at Stanford University (CA, USA), the device resembles a glucometer, with a blood drop dabbed onto a test strip inserted into one end of the device. The blood is run through a microchannel to a paper-lined well at the opposite end, which is then alkalized to release gas-phase ammonia for detection by the ammonia sensor. Ammonia levels are reported in less than two minutes. The researchers subsequently conducted a clinical study to test the device’s accuracy on both adults and children.
The results of the first-generation instrument--designed for 100 μL of blood-- showed strong correlation (97%) with an academic clinical laboratory test for plasma ammonia concentrations up to 500 μM (16 times higher than the upper limit of normal). A second-generation hand-held instrument--designed for 10–20 μL--of blood showed a near-perfect correlation (99%) with donor blood samples from healthy adults containing known amounts of added ammonium chloride, reaching up to 1000 μM. The study was published in the August 2020 issue of ACS Sensors.
"From day one, the objective was a device that would be used by patients and their families to improve health outcomes. Through all the challenges, having that goal has really held the collaborative effort together,” said co-senior author Matthew Kanan, PhD, of the department of chemistry. “The burden on the patients in our study was a powerful motivator. Some were having several tests a day for many days and every single one is a separate venous draw. It's a lot of blood and pain, and if something goes wrong with the test, it's worthless.”
Ammonia is a natural product of digestion that is usually processed into urea by the liver and passed out in urine. But if retained, hyperammonia can cause mental and physical dysfunction and is a concern for people with liver disease or genetic conditions that hinder ammonia metabolism. The new device could be especially beneficial for newborns with such metabolic diseases, as brain damage can occur within hours of elevated ammonia levels. The current test for measuring ammonia levels requires blood drawn from a vein, quickly transported on ice to an analysis lab, centrifuged to separate plasma, and then processed by a biochemical assay, with results taking at least two hours.
Related Links:
Stanford University
Developed by researchers at Stanford University (CA, USA), the device resembles a glucometer, with a blood drop dabbed onto a test strip inserted into one end of the device. The blood is run through a microchannel to a paper-lined well at the opposite end, which is then alkalized to release gas-phase ammonia for detection by the ammonia sensor. Ammonia levels are reported in less than two minutes. The researchers subsequently conducted a clinical study to test the device’s accuracy on both adults and children.
The results of the first-generation instrument--designed for 100 μL of blood-- showed strong correlation (97%) with an academic clinical laboratory test for plasma ammonia concentrations up to 500 μM (16 times higher than the upper limit of normal). A second-generation hand-held instrument--designed for 10–20 μL--of blood showed a near-perfect correlation (99%) with donor blood samples from healthy adults containing known amounts of added ammonium chloride, reaching up to 1000 μM. The study was published in the August 2020 issue of ACS Sensors.
"From day one, the objective was a device that would be used by patients and their families to improve health outcomes. Through all the challenges, having that goal has really held the collaborative effort together,” said co-senior author Matthew Kanan, PhD, of the department of chemistry. “The burden on the patients in our study was a powerful motivator. Some were having several tests a day for many days and every single one is a separate venous draw. It's a lot of blood and pain, and if something goes wrong with the test, it's worthless.”
Ammonia is a natural product of digestion that is usually processed into urea by the liver and passed out in urine. But if retained, hyperammonia can cause mental and physical dysfunction and is a concern for people with liver disease or genetic conditions that hinder ammonia metabolism. The new device could be especially beneficial for newborns with such metabolic diseases, as brain damage can occur within hours of elevated ammonia levels. The current test for measuring ammonia levels requires blood drawn from a vein, quickly transported on ice to an analysis lab, centrifuged to separate plasma, and then processed by a biochemical assay, with results taking at least two hours.
Related Links:
Stanford University
Latest Critical Care News
- Automated IV Labeling Solution Improves Infusion Safety and Efficiency
- First-Of-Its-Kind AI Tool Detects Pulmonary Hypertension from Standard ECGs
- 4D Digital Twin Heart Model Improves CRT Outcomes
- AI Turns Glucose Data Into Actionable Insights for Diabetes Care
- Microscale Wireless Implant Tracks Brain Activity Over Time
- Smart Mask Delivers Continuous, Battery-Free Breath Monitoring
- Routine Blood Pressure Readings May Identify Risk of Future Cognitive Decline
- CGM-Based Algorithm Enhances Insulin Dose Adjustment in Type 2 Diabetes
- Fish Scale–Based Implants Offer New Approach to Corneal Repair
- Dual-Function Wound Patch Combines Infection Sensing and Treatment
- Smartwatch Signals and Blood Tests Team Up for Early Warning on Insulin Resistance
- Smart Fabric Technology Aims to Prevent Pressure Injuries in Hospital Care
- Standardized Treatment Algorithm Improves Blood Pressure Control
- Combined Infection Control Strategy Limits Drug-Resistant Outbreak in NICU
- AI Helps Predict Which Heart-Failure Patients Will Worsen Within a Year
- Algorithm Allows Paramedics to Predict Brain Damage Risk After Cardiac Arrest
Channels
Artificial Intelligence
view channel
Machine Learning Approach Enhances Liver Cancer Risk Stratification
Hepatocellular carcinoma, the most common form of primary liver cancer, is often detected late despite targeted surveillance programs. Current screening guidelines emphasize patients with known cirrhosis,... Read more
New AI Approach Monitors Brain Health Using Passive Wearable Data
Brain health spans cognitive and emotional functions and can fluctuate even in adults without diagnosed disease. Detecting early changes remains difficult in routine care and burdens specialty services... Read moreSurgical Techniques
view channel
Continuous Monitoring with Wearables Enhances Postoperative Patient Safety
Postoperative hypoxemia on general surgical wards is common and often missed by intermittent vital sign checks. Undetected low oxygen levels can delay recovery and raise the risk of complications that... Read more
New Approach Enables Customized Muscle Tissue Without Biomaterial Scaffolds
Volumetric muscle loss is a traumatic loss of skeletal muscle that often leads to permanent functional impairment and limited reconstructive options. Current experimental strategies struggle to deliver... Read morePatient Care
view channel
Wearable Sleep Data Predict Adherence to Pulmonary Rehabilitation
Chronic obstructive pulmonary disease (COPD) is a long-term lung disorder that makes breathing difficult and often disturbs sleep, reducing energy for daily activities. Limited engagement in pulmonary... Read more
Revolutionary Automatic IV-Line Flushing Device to Enhance Infusion Care
More than 80% of in-hospital patients receive intravenous (IV) therapy. Every dose of IV medicine delivered in a small volume (<250 mL) infusion bag should be followed by subsequent flushing to ensure... Read moreHealth IT
view channel
EMR-Based Tool Predicts Graft Failure After Kidney Transplant
Kidney transplantation offers patients with end-stage kidney disease longer survival and better quality of life than dialysis, yet graft failure remains a major challenge. Although a successful transplant... Read more
Printable Molecule-Selective Nanoparticles Enable Mass Production of Wearable Biosensors
The future of medicine is likely to focus on the personalization of healthcare—understanding exactly what an individual requires and delivering the appropriate combination of nutrients, metabolites, and... Read moreBusiness
view channel