Cooling Device Limits Esophageal Lesions During Heart Ablations 
            
                        | By HospiMedica International staff writers Posted on 10 Aug 2020 | 

The ensoETM temperature control device (Photo courtesy of Attune Medical)
			
			Attune Medical 
St George's University of London device could minimize esophageal injury during radio frequency ablation for atrial fibrillation (AF).
The ensoETM, a product of Attune Medical (Chicago, IL, USA;) is a single-use silicone tube (similar to a standard orogastric tube) that is inserted into the esophagus to control patient temperature via a closed-loop system. The device is positioned at the core, close to the great vessels and the left atrium of the heart. Once in position, water circulates from an external heat exchange unit. The ensoETM is currently used for body-temperature control, either warming in the intensive care unit (ICU) after surgery or for burn victims, or for cooling after head trauma, cerebral hypoxia, or in cases of high fever.
In a study conducted at St George's University of London (SGUL; United Kingdom;), 188 patients were assigned to esophageal placement of the ensoETM (protected group) or a temperature probe (control group) prior to AF ablation. The results showed that mucosal injury occurred in 3.3% of protected patients and in 20% of control patients. Procedure duration averaged 186 minutes and varied between groups by less than one minute. At three months, there were no significant differences among groups in gastroparesis symptoms index or in gastroesophageal reflux disease (GERD) scores. The study was presented at the European Heart Rhythm Association Congress 2020.
“The device protected the esophagus significantly from mucosal injuries, so burns to the esophagus were significantly more common in the unprotected group,” said study presenter consultant cardiologist Mark Gallagher, MD. “Which patients would develop lesions was largely unpredictable, but there was a trend toward more lesions in patients who had a posterior wall line. Performance about that line did increase the risk of plexus injury and of mucosal injury, not surprisingly. Other than that, we were not good at predicting who's going to get a lesion.”
Esophageal injury during AF ablation accounts for about half of the mortality during the procedure, and is by far the largest cause of death. Previous strategies to protect the esophagus have been inadequate, including the use of proton pump inhibitors, to esophageal deflection, to infusing small amounts of cold water at a time into the esophagus. And esophageal temperature-monitoring probes could increase thermal injury and slow the procedure.
Related Links:
Attune Medical
St George's University of London
			
			
		
        		        
		        St George's University of London device could minimize esophageal injury during radio frequency ablation for atrial fibrillation (AF).
The ensoETM, a product of Attune Medical (Chicago, IL, USA;) is a single-use silicone tube (similar to a standard orogastric tube) that is inserted into the esophagus to control patient temperature via a closed-loop system. The device is positioned at the core, close to the great vessels and the left atrium of the heart. Once in position, water circulates from an external heat exchange unit. The ensoETM is currently used for body-temperature control, either warming in the intensive care unit (ICU) after surgery or for burn victims, or for cooling after head trauma, cerebral hypoxia, or in cases of high fever.
In a study conducted at St George's University of London (SGUL; United Kingdom;), 188 patients were assigned to esophageal placement of the ensoETM (protected group) or a temperature probe (control group) prior to AF ablation. The results showed that mucosal injury occurred in 3.3% of protected patients and in 20% of control patients. Procedure duration averaged 186 minutes and varied between groups by less than one minute. At three months, there were no significant differences among groups in gastroparesis symptoms index or in gastroesophageal reflux disease (GERD) scores. The study was presented at the European Heart Rhythm Association Congress 2020.
“The device protected the esophagus significantly from mucosal injuries, so burns to the esophagus were significantly more common in the unprotected group,” said study presenter consultant cardiologist Mark Gallagher, MD. “Which patients would develop lesions was largely unpredictable, but there was a trend toward more lesions in patients who had a posterior wall line. Performance about that line did increase the risk of plexus injury and of mucosal injury, not surprisingly. Other than that, we were not good at predicting who's going to get a lesion.”
Esophageal injury during AF ablation accounts for about half of the mortality during the procedure, and is by far the largest cause of death. Previous strategies to protect the esophagus have been inadequate, including the use of proton pump inhibitors, to esophageal deflection, to infusing small amounts of cold water at a time into the esophagus. And esophageal temperature-monitoring probes could increase thermal injury and slow the procedure.
Related Links:
Attune Medical
St George's University of London
Latest Critical Care News
- 'Universal' Kidney to Match Any Blood Type
- AI Heart Attack Risk Assessment Tool Outperforms Existing Methods
- Smartphone Imaging System Enables Early Oral Cancer Detection
- Swallowable Pill-Sized Bioprinter Treats GI Tract Injuries  
- Personalized Brain “Pacemakers” Could Help Patients with Hard-To-Treat Epilepsy
- Microscopic DNA Flower Robots to Enable Precision Medicine Delivery
- Origami Robots to Deliver Medicine Less Invasively and More Effectively
- Improved Cough-Detection Technology Aids Health Monitoring
- AI Identifies Children in ER Likely to Develop Sepsis Within 48 Hours
- New Radiofrequency Therapy Slows Glioblastoma Growth
- Battery-Free Wireless Multi-Sensing Platform Revolutionizes Pressure Injury Detection
- Multimodal AI to Revolutionize Cardiovascular Disease Diagnosis and Treatment
- AI System Reveals Hidden Diagnostic Patterns in Electronic Health Records
- Highly Sensitive On-Skin Sensing Monitor Detects Vitamin B6 and Glucose in Sweat
- Artificial Intelligence Revolutionizing Pediatric Anesthesia Management
- New Device Detects Tuberculosis DNA Directly in Exhaled Air
Channels
Surgical Techniques
view channel 
                    Minimally Invasive Endoscopic Surgery Improves Severe Stroke Outcomes
Intracerebral hemorrhage, a type of stroke caused by bleeding deep within the brain, remains one of the most challenging neurological emergencies to treat. Accounting for about 15% of all strokes, it carries... Read more 
                    Novel Glue Prevents Complications After Breast Cancer Surgery
Seroma and prolonged lymphorrhea are among the most common complications following axillary lymphadenectomy in breast cancer patients. These postoperative issues can delay recovery and postpone the start... Read morePatient Care
view channel 
                    Revolutionary Automatic IV-Line Flushing Device to Enhance Infusion Care
More than 80% of in-hospital patients receive intravenous (IV) therapy. Every dose of IV medicine delivered in a small volume (<250 mL) infusion bag should be followed by subsequent flushing to ensure... Read more 
                    VR Training Tool Combats Contamination of Portable Medical Equipment
Healthcare-associated infections (HAIs) impact one in every 31 patients, cause nearly 100,000 deaths each year, and cost USD 28.4 billion in direct medical expenses. Notably, up to 75% of these infections... Read more 
                    Portable Biosensor Platform to Reduce Hospital-Acquired Infections
Approximately 4 million patients in the European Union acquire healthcare-associated infections (HAIs) or nosocomial infections each year, with around 37,000 deaths directly resulting from these infections,... Read more 
                    First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds
Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read moreHealth IT
view channel 
                    Printable Molecule-Selective Nanoparticles Enable Mass Production of Wearable Biosensors
The future of medicine is likely to focus on the personalization of healthcare—understanding exactly what an individual requires and delivering the appropriate combination of nutrients, metabolites, and... Read moreBusiness
view channel 
                    Philips and Masimo Partner to Advance Patient Monitoring Measurement Technologies
Royal Philips (Amsterdam, Netherlands) and Masimo (Irvine, California, USA) have renewed their multi-year strategic collaboration, combining Philips’ expertise in patient monitoring with Masimo’s noninvasive... Read more 
                    B. Braun Acquires Digital Microsurgery Company True Digital Surgery
The high-end microsurgery market in neurosurgery, spine, and ENT is undergoing a significant transformation. Traditional analog microscopes are giving way to digital exoscopes, which provide improved visualization,... Read more 
                    CMEF 2025 to Promote Holistic and High-Quality Development of Medical and Health Industry
The 92nd China International Medical Equipment Fair (CMEF 2025) Autumn Exhibition is scheduled to be held from September 26 to 29 at the China Import and Export Fair Complex (Canton Fair Complex) in Guangzhou.... Read more 
                    















 
								

 
								.jpg)
 
								 
                     
                     
                    