Neuromuscular Stimulator Increases Microcirculatory Blood Flow
By HospiMedica International staff writers Posted on 28 Dec 2021 |

Image: The discrete geko device increases venous return in the legs (Photo courtesy of Sky Medical)
A wearable device increases microcirculatory blood flow in the lower limbs of patients with venous insufficiency and/or ischemia.
The Sky Medical Technology (High Wycombe, United Kingdom) geko device is a disposable wristwatch size device worn just under the knee that is designed to gently stimulate the common peroneal nerve. Due to its proximity to the posterior/anterior bifurcation, the common fibular nerve, and the external and lateral popliteal nerves, it’s stimulation results in activation of the tibialis, peroneus longus, and lateral gastrocnemius muscles. The simultaneous contraction of these muscles compresses and efficiently evacuates blood in the deep veins of the calf.
Once switched on, and the appropriate stimulation level selected, the patient is made aware of the muscle contractions, but with no change to either heart rate or blood pressure. During treatment, the uncomfortable sensation recedes after a few minutes thanks to accommodation, awareness of the muscle contractions lessens, and patients can carry on with their normal daily routine, including going to sleep. The geko device needs to be removed if the patient needs to a shower or bathe.
“Through our central strategy in partnering with healthcare professionals to solve challenging medical problems, we identify and translate clinical needs into cutting-edge products and evidence-based protocols,” said Bernard Ross, CEO of Sky Medical Technology. “The new standards of care simplify treatments for clinicians and improve patient outcomes, and new care pathways are in development in neurology, orthopedics, renal, and peripheral vascular disease.”
Venous insufficiency and ischemia relate to reduced blood flow in the veins and arteries, most often resulting from incompetent valves. Venous insufficiency can lead to lower extremity edema, skin changes, and discomfort, but if left untreated, can progress to chronic venous insufficiency (CVI), which can lead to post-phlebitic syndrome and venous leg ulcers.
Related Links:
Sky Medical Technology
The Sky Medical Technology (High Wycombe, United Kingdom) geko device is a disposable wristwatch size device worn just under the knee that is designed to gently stimulate the common peroneal nerve. Due to its proximity to the posterior/anterior bifurcation, the common fibular nerve, and the external and lateral popliteal nerves, it’s stimulation results in activation of the tibialis, peroneus longus, and lateral gastrocnemius muscles. The simultaneous contraction of these muscles compresses and efficiently evacuates blood in the deep veins of the calf.
Once switched on, and the appropriate stimulation level selected, the patient is made aware of the muscle contractions, but with no change to either heart rate or blood pressure. During treatment, the uncomfortable sensation recedes after a few minutes thanks to accommodation, awareness of the muscle contractions lessens, and patients can carry on with their normal daily routine, including going to sleep. The geko device needs to be removed if the patient needs to a shower or bathe.
“Through our central strategy in partnering with healthcare professionals to solve challenging medical problems, we identify and translate clinical needs into cutting-edge products and evidence-based protocols,” said Bernard Ross, CEO of Sky Medical Technology. “The new standards of care simplify treatments for clinicians and improve patient outcomes, and new care pathways are in development in neurology, orthopedics, renal, and peripheral vascular disease.”
Venous insufficiency and ischemia relate to reduced blood flow in the veins and arteries, most often resulting from incompetent valves. Venous insufficiency can lead to lower extremity edema, skin changes, and discomfort, but if left untreated, can progress to chronic venous insufficiency (CVI), which can lead to post-phlebitic syndrome and venous leg ulcers.
Related Links:
Sky Medical Technology
Latest Critical Care News
- Implantable Device Could Save Diabetes Patients from Dangerously Low Blood Sugar
- New Prostate Screening Device Could Replace Traditional Examination Method
- Adaptive Spine Board to Revolutionize ER Transport
- Mapping Communication Between Internal Organs to Enable Earlier Illness Diagnosis
- Intelligent Wound Dressing Reduces Inflammation and Promotes Healing
- Cuff-Free Blood Pressure Monitoring Device to Improve Early Detection and Management of Hypertension
- New Understanding of Barrett’s Esophagus Formation to Enable Earlier Intervention and Diagnosis
- 3D Printed Functional Human Islets Could Transform Type 1 Diabetes Treatment
- AI Model Predicts ICU mortality in Heart Failure Patients
- Smart Capsule Offers Real-Time Profiling Across GI Tract
- Ultra-Thin Implant Helps Patients with Spinal Cord Injury Recover Lost Functions
- Portable Cell Therapy Device to Enable Rapid On-Demand Modification of RBCs at POC
- Monitoring Airborne Fungal Spores Could Help Predict COVID-19 & Flu Surges
- New System Measures Blood Sodium Without Needles
- Sleep Data from Wearable Device May Help Predict Preterm Birth
- AI Tool Interprets Echocardiograms in Minutes
Channels
Surgical Techniques
view channel
Fluorescent Imaging Agent ‘Lights Up’ Nerves for Better Visualization During Surgery
Surgical nerve injury is a significant concern in head and neck surgeries, where nerves are at risk of being inadvertently damaged during procedures. Such injuries can lead to complications that may impact... Read more
LED-Based Imaging System Could Transform Cancer Detection in Endoscopy
Gastrointestinal cancers remain one of the most common and challenging forms of cancer to diagnose accurately. Despite the widespread use of endoscopy for screening and diagnosis, the procedure still misses... Read morePatient Care
view channel
Revolutionary Automatic IV-Line Flushing Device to Enhance Infusion Care
More than 80% of in-hospital patients receive intravenous (IV) therapy. Every dose of IV medicine delivered in a small volume (<250 mL) infusion bag should be followed by subsequent flushing to ensure... Read more
VR Training Tool Combats Contamination of Portable Medical Equipment
Healthcare-associated infections (HAIs) impact one in every 31 patients, cause nearly 100,000 deaths each year, and cost USD 28.4 billion in direct medical expenses. Notably, up to 75% of these infections... Read more
Portable Biosensor Platform to Reduce Hospital-Acquired Infections
Approximately 4 million patients in the European Union acquire healthcare-associated infections (HAIs) or nosocomial infections each year, with around 37,000 deaths directly resulting from these infections,... Read more
First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds
Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read moreHealth IT
view channel
Printable Molecule-Selective Nanoparticles Enable Mass Production of Wearable Biosensors
The future of medicine is likely to focus on the personalization of healthcare—understanding exactly what an individual requires and delivering the appropriate combination of nutrients, metabolites, and... Read more
Smartwatches Could Detect Congestive Heart Failure
Diagnosing congestive heart failure (CHF) typically requires expensive and time-consuming imaging techniques like echocardiography, also known as cardiac ultrasound. Previously, detecting CHF by analyzing... Read moreBusiness
view channel
Bayer and Broad Institute Extend Research Collaboration to Develop New Cardiovascular Therapies
A research collaboration will focus on the joint discovery of novel therapeutic approaches based on findings in human genomics research related to cardiovascular diseases. Bayer (Berlin, Germany) and... Read more