Subcutaneous Defibrillators Effective for Typical Arrhythmia
|
By HospiMedica International staff writers Posted on 04 Jan 2022 |

Image: Placement of a transvenous ICD (Photo courtesy of Mayo Clinic)
Electric shocks delivered by subcutaneous defibrillators are equally effective as shocks delivered by conventional transvenous defibrillators, according to a new study.
Researchers at Academic Medical Center (AMC; Amsterdam, The Netherlands), Emory University (Atlanta, GA, USA), Maastricht University Medical Center (MUMC; The Netherlands), and other institutions conducted a study of 849 patients in 39 centers, who were randomized to receive a subcutaneous implantable cardioverter-defibrillator (S-ICD) or a transvenous ICD (TV-ICD). ICD therapy was defined as therapy for ventricular arrhythmias, classified as discrete episodes and storm episodes.
The results showed that in the S-ICD group, 86 patients had a total of 256 episodes with appropriate ICD therapy, versus 78 patients in the TV-ICD group, with 348 episodes. There were no statistical differences in the number of patients with appropriate therapy between groups, although patients in the subcutaneous ICD group had a higher risk of shocks overall. A higher incidence of electrical storms was seen in the TV-ICD group. The study was published on November 14, 2021, in Circulation.
“For typical arrhythmias, S-ICDs are a reasonable alternative to transvenous defibrillators, which are not compatible with all patients,” said study co-author Alexandru Chicos, MD, of AMC. “They seem to be associated with a higher risk of appropriate and inappropriate shocks, but they avoid long-term intravascular hardware and potential complications associated with it. Technology under development may bring the capability of anti-tachycardia pacing to the subcutaneous defibrillator systems.”
An ICD resynchronizes the beating of the heart's lower chambers (ventricles), which often beat out of sync in heart failure patients, and provides back up treatment for sudden cardiac death (SCD).
Related Links:
Academic Medical Center
Emory University
Maastricht University Medical Center
Researchers at Academic Medical Center (AMC; Amsterdam, The Netherlands), Emory University (Atlanta, GA, USA), Maastricht University Medical Center (MUMC; The Netherlands), and other institutions conducted a study of 849 patients in 39 centers, who were randomized to receive a subcutaneous implantable cardioverter-defibrillator (S-ICD) or a transvenous ICD (TV-ICD). ICD therapy was defined as therapy for ventricular arrhythmias, classified as discrete episodes and storm episodes.
The results showed that in the S-ICD group, 86 patients had a total of 256 episodes with appropriate ICD therapy, versus 78 patients in the TV-ICD group, with 348 episodes. There were no statistical differences in the number of patients with appropriate therapy between groups, although patients in the subcutaneous ICD group had a higher risk of shocks overall. A higher incidence of electrical storms was seen in the TV-ICD group. The study was published on November 14, 2021, in Circulation.
“For typical arrhythmias, S-ICDs are a reasonable alternative to transvenous defibrillators, which are not compatible with all patients,” said study co-author Alexandru Chicos, MD, of AMC. “They seem to be associated with a higher risk of appropriate and inappropriate shocks, but they avoid long-term intravascular hardware and potential complications associated with it. Technology under development may bring the capability of anti-tachycardia pacing to the subcutaneous defibrillator systems.”
An ICD resynchronizes the beating of the heart's lower chambers (ventricles), which often beat out of sync in heart failure patients, and provides back up treatment for sudden cardiac death (SCD).
Related Links:
Academic Medical Center
Emory University
Maastricht University Medical Center
Latest Critical Care News
- Automated IV Labeling Solution Improves Infusion Safety and Efficiency
- First-Of-Its-Kind AI Tool Detects Pulmonary Hypertension from Standard ECGs
- 4D Digital Twin Heart Model Improves CRT Outcomes
- AI Turns Glucose Data Into Actionable Insights for Diabetes Care
- Microscale Wireless Implant Tracks Brain Activity Over Time
- Smart Mask Delivers Continuous, Battery-Free Breath Monitoring
- Routine Blood Pressure Readings May Identify Risk of Future Cognitive Decline
- CGM-Based Algorithm Enhances Insulin Dose Adjustment in Type 2 Diabetes
- Fish Scale–Based Implants Offer New Approach to Corneal Repair
- Dual-Function Wound Patch Combines Infection Sensing and Treatment
- Smartwatch Signals and Blood Tests Team Up for Early Warning on Insulin Resistance
- Smart Fabric Technology Aims to Prevent Pressure Injuries in Hospital Care
- Standardized Treatment Algorithm Improves Blood Pressure Control
- Combined Infection Control Strategy Limits Drug-Resistant Outbreak in NICU
- AI Helps Predict Which Heart-Failure Patients Will Worsen Within a Year
- Algorithm Allows Paramedics to Predict Brain Damage Risk After Cardiac Arrest
Channels
Artificial Intelligence
view channel
Machine Learning Approach Enhances Liver Cancer Risk Stratification
Hepatocellular carcinoma, the most common form of primary liver cancer, is often detected late despite targeted surveillance programs. Current screening guidelines emphasize patients with known cirrhosis,... Read more
New AI Approach Monitors Brain Health Using Passive Wearable Data
Brain health spans cognitive and emotional functions and can fluctuate even in adults without diagnosed disease. Detecting early changes remains difficult in routine care and burdens specialty services... Read moreSurgical Techniques
view channel
Continuous Monitoring with Wearables Enhances Postoperative Patient Safety
Postoperative hypoxemia on general surgical wards is common and often missed by intermittent vital sign checks. Undetected low oxygen levels can delay recovery and raise the risk of complications that... Read more
New Approach Enables Customized Muscle Tissue Without Biomaterial Scaffolds
Volumetric muscle loss is a traumatic loss of skeletal muscle that often leads to permanent functional impairment and limited reconstructive options. Current experimental strategies struggle to deliver... Read morePatient Care
view channel
Wearable Sleep Data Predict Adherence to Pulmonary Rehabilitation
Chronic obstructive pulmonary disease (COPD) is a long-term lung disorder that makes breathing difficult and often disturbs sleep, reducing energy for daily activities. Limited engagement in pulmonary... Read more
Revolutionary Automatic IV-Line Flushing Device to Enhance Infusion Care
More than 80% of in-hospital patients receive intravenous (IV) therapy. Every dose of IV medicine delivered in a small volume (<250 mL) infusion bag should be followed by subsequent flushing to ensure... Read moreHealth IT
view channel
EMR-Based Tool Predicts Graft Failure After Kidney Transplant
Kidney transplantation offers patients with end-stage kidney disease longer survival and better quality of life than dialysis, yet graft failure remains a major challenge. Although a successful transplant... Read more
Printable Molecule-Selective Nanoparticles Enable Mass Production of Wearable Biosensors
The future of medicine is likely to focus on the personalization of healthcare—understanding exactly what an individual requires and delivering the appropriate combination of nutrients, metabolites, and... Read moreBusiness
view channel