Ingestible X-Ray Capsule Could Address Issues in Preventive Screenings for Colonoscopies
|
By HospiMedica International staff writers Posted on 03 Feb 2022 |

An ingestible ultra-low dose X-ray capsule aims to significantly increase colorectal cancer (CRC) screening adherence worldwide and help millions of people to stay healthy through preventive screening.
Check-Cap Ltd.’s (Isfiya, Israel; www.check-cap.com) C-Scan system is the first and only preparation-free test to detect precancerous polyps and enable early intervention and cancer prevention. A large part of the screening age population avoids standard screening procedures such as colonoscopy. C-Scan system has the potential to offer a more patient-friendly option, enabling people to get the screening they need.
Once the ingestible capsule C-Scan Cap is swallowed, it travels naturally along the gastrointestinal tract while scanning the inner lining of the colon. C-Scan Cap actively communicates with the second element of the system, C-Scan Track, which records and stores the scanning data. When the screening procedure is over, C-Scan Cap will be excreted naturally, the patient is notified, and the scanning data can be analyzed by using the company’s proprietary software, C-Scan View.
The C-Scan’s technology is based on two physical phenomena related to the interaction of the X-ray photons emitted by the capsule with the contents of the colon and the tissue wall. The first is X-ray fluorescence: When X-ray photons interact with the ingested contrast agent that mixes with the colon content, secondary X-ray fluorescence photons are generated, some of which are back scattered and detected by the x-ray detectors in the capsule. The second phenomenon is Compton scattering: When emitted X-ray photons interact with electrons of atoms in the colon wall and lumen some of the photons scattered by this mechanism head back in the direction of the capsule with an energy correlated to their angle of scatter.
The number of detected X-ray fluorescence photons and Compton back-scattered photons is correlated to the distance between the capsule and the colon wall. As the distance between the capsule and the colon wall increases, presence of content induces higher rates of X-ray fluorescence photons. At the same time, the content attenuates Compton back-scattered photons, hence decreasing the corresponding detection rate. The close proximity of the capsule to the scanning target allows for the use of an ultra-low dose radiation, since a very low x-ray flux is required to obtain sufficient signal-to-noise ratio and good scanning quality.
In a multi-center, open label prospective study, the C-Scan System demonstrated high sensitivity and specificity for the detection of precancerous polyps when compared to FIT (fecal immunochemical test), a commonly used non-invasive colorectal cancer screening test. Colonoscopy was used as the reference method.
"Our prospective single-arm pilot study demonstrated positive safety results and high patient satisfaction with a new and unique preparation-free colon capsule system intended for detection of colorectal polyps and masses," said Elizabeth Rajan, M.D., principal investigator of the study, gastroenterologist and professor of medicine, Mayo Clinic, Rochester. "This study represents a step forward to a prepless approach for CRC screening that may overcome one of the most important deterrents to screening. A multicenter pivotal study is planned in the U.S. to further validate the performance of this technology."
Related Links:
Check-Cap Ltd.
Latest Surgical Techniques News
- Ultrasound Technology Aims to Replace Invasive BPH Procedures
- Continuous Monitoring with Wearables Enhances Postoperative Patient Safety
- New Approach Enables Customized Muscle Tissue Without Biomaterial Scaffolds
- Robot-Assisted Brain Angiography Improves Procedural Outcomes
- Brain Mapping Technology Enhances Precision in Brain Tumor Resection
- Handheld Robotic System Expands Options for Total Knee Surgery
- VR Experience Reduces Patient Anxiety Before Kidney Stone Procedure
- Injectable Mini Livers Offer Hope for Patients Awaiting Transplant
- Pulsed Field Ablation Technology Cleared in Europe for Persistent AFib
- AI-Powered Imaging Brings Real-Time Margin Clarity to Breast Cancer Surgery
- Minimally Invasive Device Safely Treats Challenging Brain Aneurysms
- Surgical Robot Makes Complex Liver Tumor Surgery Safer and Less Invasive
- Neurostimulation Implant Reduces Seizure Burden in Drug-Resistant Epilepsy
- Minimally Invasive Procedure Effectively Treats Small Kidney Cancers
- Fluorescence Probe Paired with Engineered Enzymes Lights Up Tumors for Easier Surgical Removal
- Novel Hydrogel Could Become Bone Implant of the Future
Channels
Artificial Intelligence
view channelAI Analysis of Pericardial Fat Refines Long-Term Heart Disease Risk
Accurately identifying long-term cardiovascular disease risk in asymptomatic adults remains challenging for clinicians. Missed or underestimated risk delays preventive therapy and increases the chance... Read more
Machine Learning Approach Enhances Liver Cancer Risk Stratification
Hepatocellular carcinoma, the most common form of primary liver cancer, is often detected late despite targeted surveillance programs. Current screening guidelines emphasize patients with known cirrhosis,... Read moreCritical Care
view channel
Noninvasive Monitoring Device Enables Earlier Intervention in Heart Failure
Hospitalizations for heart failure with preserved ejection fraction (HFpEF) remain common because lung congestion often worsens before symptoms prompt treatment changes. Missed early decompensation... Read more
Automated IV Labeling Solution Improves Infusion Safety and Efficiency
Medication administration in high-acuity settings is often complicated by multiple concurrent infusions, making accurate line identification essential. In a 10-hospital intensive care unit study, 60% of... Read morePatient Care
view channel
Wearable Sleep Data Predict Adherence to Pulmonary Rehabilitation
Chronic obstructive pulmonary disease (COPD) is a long-term lung disorder that makes breathing difficult and often disturbs sleep, reducing energy for daily activities. Limited engagement in pulmonary... Read more
Revolutionary Automatic IV-Line Flushing Device to Enhance Infusion Care
More than 80% of in-hospital patients receive intravenous (IV) therapy. Every dose of IV medicine delivered in a small volume (<250 mL) infusion bag should be followed by subsequent flushing to ensure... Read moreHealth IT
view channel
EMR-Based Tool Predicts Graft Failure After Kidney Transplant
Kidney transplantation offers patients with end-stage kidney disease longer survival and better quality of life than dialysis, yet graft failure remains a major challenge. Although a successful transplant... Read more
Printable Molecule-Selective Nanoparticles Enable Mass Production of Wearable Biosensors
The future of medicine is likely to focus on the personalization of healthcare—understanding exactly what an individual requires and delivering the appropriate combination of nutrients, metabolites, and... Read moreBusiness
view channel