Ultraflexible, Gas-Permeable Thermistors to Pave Way for On-Skin Medical Sensors and Implantable Devices
|
By HospiMedica International staff writers Posted on 30 Sep 2022 |

On-skin medical sensors and wearable health devices are important health care tools that must be incredibly flexible and ultrathin so they can move with the human body. In addition, the technology has to withstand bending and stretching, and it needs to be gas-permeable to prevent irritation and discomfort. Another important safety feature of these devices is the required overheat protection circuit. This prevents the devices from overheating and burning the wearer. Any new technology developed for these sensors must meet these needs. Now, researchers have demonstrated how an important component of the sensors called a thermistor can be constructed using an ultrathin fiber-mesh, paving the way for ultraflexible and gas-permeable thermistors that can act as overheat prevention components for on-skin or implantable devices.
Thermistors are a type of resistor whose resistance significantly varies with temperature. For such thermistors to be applied for on-skin medical sensors, they must be stretchable and bendable down to several hundred micrometers. It is important for this technology to be able to wrap around a needle because sometimes sensors are attached to needles or catheters while in use. In order to achieve this, the thermistor needs to be ultrathin. Researchers at Shinshu University (Matsumoto, Japan) used a technique called electrospinning to create the ultrathin mesh-type polymer PTC thermistor. Electrospinning uses electricity to create tiny fibers. The fibers can be made out of different materials, but in this case, researchers used a solution of composite materials.
The newly designed thermistor was then tested to ensure it achieved similar performance capabilities of existing technology. Like typical film-type thermistors, the mesh-type polymer PTC thermistor showed an increase in resistance of three orders of magnitude, an important characteristic for preventing overheating and burns. By using a mesh structure, the thermistor also achieved transparency, which can help the sensors blend into the skin, and gas-permeability. Gas-permeability is necessary because it prevents irritation and discomfort. Even with this fiber layer, which serves to give the mesh structure and additional heat sensing, the thermistor remained very thin. This is important because any wearable medical device must be able to withstand bending and when the device is thinner, there is less strain.
Though this thermistor technology is promising, more research will need to be done to make this a reliable alternative to the current thermistor technology on the market. A mesh-type thermistor has a high initial resistance value due to its limited number of conductive paths. The researchers proposed that reducing the spacing between fibers in the mesh or increasing the number of electrodes used could resolve some of these problems, but additional testing will need to be done.
“An overheat protection circuit is required to avoid burning biological tissues during the operation of flexible devices. One candidate is a polymer positive temperature coefficient (PTC) thermistor, which has a large increase in resistance within a narrow temperature range,” said Chihiro Okutani, an assistant professor in the Department of Electrical and Computer Engineering at Shinshu University in Japan. “For such thermistors to be applied for on-skin medical sensors, they must be stretchable and bendable down to several hundred micrometers. However, it is still challenging to fabricate a thermistor whose temperature characteristics do not deteriorate when wrapped around a needle with a bending radius of less than 1 mm.”
“We also demonstrated the operation of the thermistor wrapped around a 280-micrometer needle by fabricating the fibers on a 1.4 micrometer ultrathin film,” added Okutani. “Our next step is practical applications of the developed thermistors. We believe that the ultraflexible and gas-permeable thermistors can act as overheat prevention components for on-skin or implantable devices, which make flexible sensors safer to operate and more reliable.”
Related Links:
Shinshu University
Latest Critical Care News
- Angiography-Based FFR Approach Matches Gold Standard Results Without Wires
- Eye Imaging AI Identifies Elevated Cardiovascular Risk
- Noninvasive Monitoring Device Enables Earlier Intervention in Heart Failure
- Automated IV Labeling Solution Improves Infusion Safety and Efficiency
- First-Of-Its-Kind AI Tool Detects Pulmonary Hypertension from Standard ECGs
- 4D Digital Twin Heart Model Improves CRT Outcomes
- AI Turns Glucose Data Into Actionable Insights for Diabetes Care
- Microscale Wireless Implant Tracks Brain Activity Over Time
- Smart Mask Delivers Continuous, Battery-Free Breath Monitoring
- Routine Blood Pressure Readings May Identify Risk of Future Cognitive Decline
- CGM-Based Algorithm Enhances Insulin Dose Adjustment in Type 2 Diabetes
- Fish Scale–Based Implants Offer New Approach to Corneal Repair
- Dual-Function Wound Patch Combines Infection Sensing and Treatment
- Smartwatch Signals and Blood Tests Team Up for Early Warning on Insulin Resistance
- Smart Fabric Technology Aims to Prevent Pressure Injuries in Hospital Care
- Standardized Treatment Algorithm Improves Blood Pressure Control
Channels
Artificial Intelligence
view channelAI Analysis of Pericardial Fat Refines Long-Term Heart Disease Risk
Accurately identifying long-term cardiovascular disease risk in asymptomatic adults remains challenging for clinicians. Missed or underestimated risk delays preventive therapy and increases the chance... Read more
Machine Learning Approach Enhances Liver Cancer Risk Stratification
Hepatocellular carcinoma, the most common form of primary liver cancer, is often detected late despite targeted surveillance programs. Current screening guidelines emphasize patients with known cirrhosis,... Read moreSurgical Techniques
view channel
Fiber-Form Bone Graft Expands Intraoperative Options for Spinal Fusion
Spinal and orthopedic fusion procedures often require bone graft materials that handle predictably and support bone formation. Surgeons face added complexity in difficult anatomy and challenging fusion environments.... Read more
Ultrasound‑Aided Catheter Treatment Cuts Early Collapse in Pulmonary Embolism
Acute pulmonary embolism can cause rapid hemodynamic deterioration and early death in hospitalized and emergency patients. Systemic thrombolysis can dissolve clots but is limited by a high risk of major... Read morePatient Care
view channel
Wearable Sleep Data Predict Adherence to Pulmonary Rehabilitation
Chronic obstructive pulmonary disease (COPD) is a long-term lung disorder that makes breathing difficult and often disturbs sleep, reducing energy for daily activities. Limited engagement in pulmonary... Read more
Revolutionary Automatic IV-Line Flushing Device to Enhance Infusion Care
More than 80% of in-hospital patients receive intravenous (IV) therapy. Every dose of IV medicine delivered in a small volume (<250 mL) infusion bag should be followed by subsequent flushing to ensure... Read moreHealth IT
view channel
Voice-Driven AI System Enables Structured GI Procedure Documentation
Documentation during gastrointestinal (GI) procedures often competes with real-time clinical decision-making and imposes a significant cognitive burden on physicians. Manual data entry and post-procedure... Read more
EMR-Based Tool Predicts Graft Failure After Kidney Transplant
Kidney transplantation offers patients with end-stage kidney disease longer survival and better quality of life than dialysis, yet graft failure remains a major challenge. Although a successful transplant... Read more
Printable Molecule-Selective Nanoparticles Enable Mass Production of Wearable Biosensors
The future of medicine is likely to focus on the personalization of healthcare—understanding exactly what an individual requires and delivering the appropriate combination of nutrients, metabolites, and... Read moreBusiness
view channel