We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

HospiMedica

Download Mobile App
Recent News AI Critical Care Surgical Techniques Patient Care Health IT Point of Care Business Focus

UV Activated Glue Helps Patch Holes in the Heart

By HospiMedica International staff writers
Posted on 12 Oct 2015
A specialized catheter for repairing congenital atrial septal defects (ASDs) utilizes UV light technology to activate a biodegradable adhesive.

Developed by researchers at Boston Children’s Hospital (BCH; MA, USA), the Wyss Institute for Biologically Inspired Engineering (Boston, MA, USA), and Brigham and Women's Hospital (Boston, MA, USA), the catheter-based technology has no implantable rigid components, functioning instead by unfolding and attaching an adhesive-loaded elastic patch via catheter. Over time, normal tissue growth resumes and heart tissue grows over the patch; the patch itself dissolves when it is no longer needed.

Image: UV light applied via the catheter to the patch (Photo courtesy of Boston Children’s Hospital).
Image: UV light applied via the catheter to the patch (Photo courtesy of Boston Children’s Hospital).

The catheter is first inserted percutaneously and directed to the ASD. Once in place, the clinician deploying a double-balloon, one around the front end of the catheter, passed through the ASD, and another at the rear. After inflation, the clinician turns on a fiber-optic UV light which is reflected off the balloons metallic coating to activate the patch’s adhesive coating. As the glue cures, pressure from the positioning balloons on either side of the patch help secure it in place. Both balloons are then deflated and the catheter is withdrawn.

The researchers demonstrated closure on the distal side of a defect in porcine abdominal wall, stomach, and heart tissue ex vivo. The catheter was further evaluated in rat heart and abdomen. According to the researchers, patches attached to the heart and abdominal wall with the device showed similar inflammatory response as sutures, with 100% small animal survival. In the porcine model, a ventricular septal defect in a beating heart was reduced to less than 1.6 mm. The study describing the system was published on September 23, 2015, in Science Translational Medicine.

“In addition to avoiding open heart surgery, this method avoids suturing into the heart tissue, because we’re just gluing something to it,” said contributing author Pedro del Nido, MD, chief of cardiac surgery at BCH. “The device represents a radical change in the way these kinds of cardiac defects are repaired; we don’t have to stop the heart. This will enable a wide range of cardiac procedures in the future.”

An ASD is a congenital defect resulting from an abnormal formation of the septum that divides the upper chamber into a left and right atrium. This results in blood flow between the two upper heart chambers through the ASD, forming a shunt. As a result, pressure in the lungs may build up, causing less oxygen in the blood. Symptoms can include difficulty breathing, frequent respiratory infections in children, palpitation, and shortness of breath with activity.

Related Links:

Boston Children’s Hospital
Wyss Institute for Biologically Inspired Engineering
Brigham and Women's Hospital



Gold Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Gold Member
12-Channel ECG
CM1200B
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
CT Phantom
CIRS Model 610 AAPM CT Performance Phantom

Latest Surgical Techniques News

Flexible Microdisplay Visualizes Brain Activity in Real-Time To Guide Neurosurgeons

Next-Gen Computer Assisted Vacuum Thrombectomy Technology Rapidly Removes Blood Clots

Hydrogel-Based Miniaturized Electric Generators to Power Biomedical Devices