Miniature Heart Pump Provides Hemodynamic Support in Coronary Interventions
|
By HospiMedica International staff writers Posted on 25 Mar 2009 |
Results from a clinical trial of the world's smallest circulatory assist device show that it provides excellent hemodynamic support during high-risk percutaneous coronary interventions (PCIs).
Researchers from Brigham and Women's Hospital (Boston, MA, USA), Massachusetts General Hospital (MGH; Boston, USA), the Texas Heart Institute (Houston, USA), and four other hospitals enrolled 20 patients undergoing high-risk PCI in the PROTECT I study between July 2006 and April 2007. Eligible patients for implantation of the Impella 2.5 circulatory assist device had left ventricular ejection fraction (EF) of less than 35% and were required to undergo PCI on either an unprotected left main coronary artery or the last patent coronary conduit. The primary safety end point was the incidence of major adverse cardiac events at 30 days; the primary efficacy end point was freedom from hemodynamic compromise during PCI, defined as a decrease in mean arterial pressure below 60 mm Hg for over 10 minutes.
The results of the study showed that the Impella 2.5 device was implanted successfully in all patients. The mean duration of circulatory support was 1.7 hours. Mean pump flow during PCI was 2.2 liters per minute. At 30 days, the incidence of major adverse cardiac events was 20%; 2 patients had a periprocedural myocardial infarction (MI), and 2 patients died at days 12 and 14. There was no evidence of aortic valve injury, cardiac perforation, or limb ischemia. Two patients (10%) developed mild, transient hemolysis without clinical sequelae. None of the patients developed hemodynamic compromise during PCI. The study was published in the February 2009 issue of the Journal of American College of Cardiology (JACC).
"The Impella 2.5 is poised to change the standard of care in our efforts to combat heart disease and its devastating after-effects," said participating cardiologist Igor Palacios, M.D., director of interventional cardiology at MGH. "The PROTECT I trial enrolled a very sick patient population and demonstrated that the device works and validated its impressive safety profile, showing no valve, blood or vascular damage, no instances of stroke and a low adverse event rate."
The Impella 2.5, a product of Abiomed (Danvers, MA, USA) is intended for partial circulatory support for periods of up to six hours. It is inserted percutaneously in the catheterization lab via the femoral artery into the left ventricle. Up to 2.5 liters of blood per minute are delivered by the pump from the left ventricle into the ascending aorta, providing the heart with active support in critical situations. The device has been approved by the European Community (CE Marking) and the U.S. Food and Drug Administration (FDA), among others.
Related Links:
Brigham and Women's Hospital
Massachusetts General Hospital
Texas Heart Institute
Abiomed
Researchers from Brigham and Women's Hospital (Boston, MA, USA), Massachusetts General Hospital (MGH; Boston, USA), the Texas Heart Institute (Houston, USA), and four other hospitals enrolled 20 patients undergoing high-risk PCI in the PROTECT I study between July 2006 and April 2007. Eligible patients for implantation of the Impella 2.5 circulatory assist device had left ventricular ejection fraction (EF) of less than 35% and were required to undergo PCI on either an unprotected left main coronary artery or the last patent coronary conduit. The primary safety end point was the incidence of major adverse cardiac events at 30 days; the primary efficacy end point was freedom from hemodynamic compromise during PCI, defined as a decrease in mean arterial pressure below 60 mm Hg for over 10 minutes.
The results of the study showed that the Impella 2.5 device was implanted successfully in all patients. The mean duration of circulatory support was 1.7 hours. Mean pump flow during PCI was 2.2 liters per minute. At 30 days, the incidence of major adverse cardiac events was 20%; 2 patients had a periprocedural myocardial infarction (MI), and 2 patients died at days 12 and 14. There was no evidence of aortic valve injury, cardiac perforation, or limb ischemia. Two patients (10%) developed mild, transient hemolysis without clinical sequelae. None of the patients developed hemodynamic compromise during PCI. The study was published in the February 2009 issue of the Journal of American College of Cardiology (JACC).
"The Impella 2.5 is poised to change the standard of care in our efforts to combat heart disease and its devastating after-effects," said participating cardiologist Igor Palacios, M.D., director of interventional cardiology at MGH. "The PROTECT I trial enrolled a very sick patient population and demonstrated that the device works and validated its impressive safety profile, showing no valve, blood or vascular damage, no instances of stroke and a low adverse event rate."
The Impella 2.5, a product of Abiomed (Danvers, MA, USA) is intended for partial circulatory support for periods of up to six hours. It is inserted percutaneously in the catheterization lab via the femoral artery into the left ventricle. Up to 2.5 liters of blood per minute are delivered by the pump from the left ventricle into the ascending aorta, providing the heart with active support in critical situations. The device has been approved by the European Community (CE Marking) and the U.S. Food and Drug Administration (FDA), among others.
Related Links:
Brigham and Women's Hospital
Massachusetts General Hospital
Texas Heart Institute
Abiomed
Latest Surgical Techniques News
- Expandable Lumbar Fusion System Gains FDA 510(k) Clearance
- 3D Map of Heart Electrical Wiring Aims to Guide Congenital Heart Repair
- New CAR T-Cell Therapy Enables Transplants in Hard-to-Match Kidney Patients
- CE-Marked Ultrasonic Shears Streamline Breast and Thyroid Surgery
- Small Cryoprobe Outperforms Forceps in Lung Biopsy Trial
- Natural Bypass Score May Guide Care in Chronic Coronary Blockages
- Navigation Instruments Cleared for Posterior Cervical Fusion Procedures
- Bioengineered Heart Patch Improves Cardiac Function in Advanced Heart Failure
- Fracture Plating System Combines Anatomical Fit with Streamlined Instrumentation
- Surgical Robotic System Gains CE Mark for Minimally Invasive Procedures
- Pink Noise Stimulation Approach Could Support Safer Anesthesia
- BD Launches Elyra Laser Platform for Kidney Stone and Soft Tissue Procedures
- Anesthesia-Sparing System Targets Faster Ureteral Stone Treatment
- Stretchable Bioelectronic Implant Lowers Blood Pressure in Preclinical Study
- FDA-Cleared Nerve Stimulator Advances Intraoperative Peripheral Nerve Assessment
- Intravascular Lithotripsy Catheter Advances Treatment of Calcified Coronary Disease
Channels
Artificial Intelligence
view channel
AI Platform Supports Noninvasive Remote Hemodynamic Monitoring in Heart Failure
Heart failure remains a leading cause of hospitalization in adults over 65, affecting more than 6.7 million people in the U.S. Clinicians often lose visibility into hemodynamic deterioration once patients... Read more
AI Tool Predicts Unplanned Care and Symptom Burden in Cancer Survivors
Unplanned emergency visits and hospitalizations remain common in cancer survivorship, when routine clinical contact often tapers while new symptoms emerge. These events reflect unmet needs and disrupt... Read moreCritical Care
view channel
Home Blood Pressure Telemonitoring Linked to Fewer Cardiovascular Events
Hypertension is a leading cause of myocardial infarction and stroke, yet it often progresses without symptoms. Uncontrolled blood pressure contributes to avoidable hospitalizations, deaths, and health system burden.... Read more
Tiny Wearable Patch Tracks Heart and Respiratory Changes at Home
Auscultation and cardiorespiratory monitoring are typically limited to brief, clinic-based assessments. These intermittent checks can miss evolving abnormalities and place added burden on patients who... Read morePatient Care
view channel
AI Avatar Doctor Improves Patient Understanding Before Radiotherapy
Radiation oncology consultations require patients to grasp complex concepts quickly, yet anxiety and information overload often undermine understanding and informed consent. Poor comprehension can also... Read more
Wearable Sleep Data Predict Adherence to Pulmonary Rehabilitation
Chronic obstructive pulmonary disease (COPD) is a long-term lung disorder that makes breathing difficult and often disturbs sleep, reducing energy for daily activities. Limited engagement in pulmonary... Read moreHealth IT
view channel
AI-Native EHR Achieves EU Medical Device Certification
InterSystems (Boston, MA, USA) announced that its IntelliCare electronic health record (EHR) solutions have been certified as Class IIa medical devices under the European Union Medical Device Regulation... Read more
EHR-Integrated Screening Workflow Detects Cognitive Impairment at Admission
Cognitive impairment involves difficulties with thinking, learning, memory, and decision-making, and is more common in older adults. In U.S. hospitals, more than 40% of admitted older adults have dementia,... Read morePoint of Care
view channel
Handheld AI Device for Point-of-Care Skin Lesion Assessment Receives CE Mark
DermaSensor (Miami, FL, USA) has received a Class IIb CE Mark for its handheld DermaSensor device, marking the start of the company’s global expansion strategy. The certification demonstrates conformity... Read more
Portable Immunoassay System Advances Toward Point-of-Care Biomarker Testing
Proxim Diagnostics Corp. (Santa Clara, CA, USA) has announced that its Profile System, a handheld point-of-care immunoassay platform, has completed development. The milestone includes completion... Read more
Portable MRI System Accelerates Emergency Brain Imaging and Triage
Emergency departments frequently face delays accessing conventional magnetic resonance imaging (MRI) for patients with suspected neurological emergencies. Such waits can slow triage, prolong boarding,... Read more