A new study shows that using an intrauterine balloon is associated with a significantly lower need for invasive procedures for hemorrhage control in women following vaginal delivery.

Researchers at Université de Versailles Saint-Quentin-en-Yvelines (UVSQ; France) conducted a retrospective cohort study that included 72,529 women who delivered a baby during 2011 and 2012 in 19 maternity units in two French perinatal networks; one that routinely used an intrauterine balloon tamponade for postpartum hemorrhage management (study cohort), and another that did not (control). Postpartum outcomes were assessed based on discharge abstract data from the French national medical information system.

The results revealed that invasive procedures were assumed in 298 women, representing 4.1 per 1,000 deliveries. The cohort network had a significantly lower proportion of women with at least one invasive procedure (3/1,000), compared to the control network (5.1/1,000). The study perinatal network also had significantly lower use of arterial embolization for those who delivered vaginally. Risk of an invasive procedure remained significantly lower in the cohort network for women who delivered vaginally, but not for women who delivered by Cesarean section. The study was published on December 4, 2017, in Obstetrics & Gynecology.

“The use of intrauterine balloon tamponade in routine clinical practice is associated with a significantly lower use of invasive procedures among women undergoing vaginal delivery,” concluded lead author Mathilde Revert, MSc, and colleagues. “After controlling for potential confounding factors, the risk of an invasive procedure among women who delivered vaginally remained significantly lower in the pilot network, but not for women who delivered by Cesarean.”

Postpartum hemorrhage is the leading direct cause of maternal death worldwide. Intrauterine balloon tamponade is a minimally invasive intervention that involves inserting a balloon device into the uterus and then incrementally filling it with liquid, which applies pressure to the uterus until the bleeding stops. Even when it cannot completely control severe postpartum hemorrhage, it can still serve a critical role by reducing blood loss until the woman can be transported to a facility with surgical management and other treatment options.

Related Links:
Université de Versailles Saint-Quentin-en-Yvelines

Gold Member
12-Channel ECG
CM1200B
Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
New
Hemodynamic Monitoring Sensor
FloTrac
New
Pressure Monitoring Mattress
Entrix NX

Print article

Channels

Patient Care

view channel
Image: The portable biosensor platform uses printed electrochemical sensors for the rapid, selective detection of Staphylococcus aureus (Photo courtesy of AIMPLAS)

Portable Biosensor Platform to Reduce Hospital-Acquired Infections

Approximately 4 million patients in the European Union acquire healthcare-associated infections (HAIs) or nosocomial infections each year, with around 37,000 deaths directly resulting from these infections,... Read more