Venous Support System Improves CABG Outcomes
By HospiMedica International staff writers Posted on 02 Dec 2021 |

Image: The venous external support (VEST) system (Photo courtesy of VGS)
A novel device could lead to increased longevity and durability of saphenous vein grafts (SVG) during coronary artery bypass graft (CABG) surgery, according to a new study.
The venous external support (VEST) system, under development by Vascular Graft Solutions (VGS; Tel Aviv, Israel) is a fine, kink-resistant cobalt-chromium wire mesh that is placed over a SVG to prevent non-uniform graft dilatation post-implantation, mitigate formation of disturbed blood flow patterns, and prevent subsequent development of intimal hyperplasia. Two models are available (VEST and VEST 2.0); VEST 2.0 is more pliable, as it is braided of thinner wires, and can be cut intraoperatively by the surgeon to fit desired SVG length.
The results of a recent randomized, controlled, clinical trial comparing VEST supported and non-supported vein grafts up to five years post CABG demonstrated that VEST can mitigate pathological remodeling of SVGs, significantly reduce intimal hyperplasia and lumen irregularities, and improves blood flow hemodynamics. The study was presented as a late-breaking clinical trial during the virtual American Heart Association Scientific Sessions, broadcast from Dallas (TX, USA) during November 2021.
“Vein grafts have a limited durability; about half of them will be closed ten years after CABG. We need to find a solution to improve outcomes of surgery and prevent complications and repeated procedures,” said lead author and study presenter John Puskas, MD, chair of cardiovascular surgery at Mount Sinai Morningside (NY, NY, USA). “Among patients with complete intravascular ultrasound data, VEST was associated with statistically reduced intimal hyperplasia.”
SVGs are the most frequently used bypass conduits in CABG surgery. But saphenous veins normally experience low pressure in the leg; the higher-pressure environment of the coronary arteries can cause intimal hyperplasia, which promotes atherosclerosis and may lead to eventual closure. SVG failure rates range from 35% to 50% (five to ten years following CABG surgery), doubling the risk for re-intervention.
Related Links:
Vascular Graft Solutions
The venous external support (VEST) system, under development by Vascular Graft Solutions (VGS; Tel Aviv, Israel) is a fine, kink-resistant cobalt-chromium wire mesh that is placed over a SVG to prevent non-uniform graft dilatation post-implantation, mitigate formation of disturbed blood flow patterns, and prevent subsequent development of intimal hyperplasia. Two models are available (VEST and VEST 2.0); VEST 2.0 is more pliable, as it is braided of thinner wires, and can be cut intraoperatively by the surgeon to fit desired SVG length.
The results of a recent randomized, controlled, clinical trial comparing VEST supported and non-supported vein grafts up to five years post CABG demonstrated that VEST can mitigate pathological remodeling of SVGs, significantly reduce intimal hyperplasia and lumen irregularities, and improves blood flow hemodynamics. The study was presented as a late-breaking clinical trial during the virtual American Heart Association Scientific Sessions, broadcast from Dallas (TX, USA) during November 2021.
“Vein grafts have a limited durability; about half of them will be closed ten years after CABG. We need to find a solution to improve outcomes of surgery and prevent complications and repeated procedures,” said lead author and study presenter John Puskas, MD, chair of cardiovascular surgery at Mount Sinai Morningside (NY, NY, USA). “Among patients with complete intravascular ultrasound data, VEST was associated with statistically reduced intimal hyperplasia.”
SVGs are the most frequently used bypass conduits in CABG surgery. But saphenous veins normally experience low pressure in the leg; the higher-pressure environment of the coronary arteries can cause intimal hyperplasia, which promotes atherosclerosis and may lead to eventual closure. SVG failure rates range from 35% to 50% (five to ten years following CABG surgery), doubling the risk for re-intervention.
Related Links:
Vascular Graft Solutions
Latest Surgical Techniques News
- Pioneering Sutureless Coronary Bypass Technology to Eliminate Open-Chest Procedures
- Intravascular Imaging for Guiding Stent Implantation Ensures Safer Stenting Procedures
- World's First AI Surgical Guidance Platform Allows Surgeons to Measure Success in Real-Time
- AI-Generated Synthetic Scarred Hearts Aid Atrial Fibrillation Treatment
- New Class of Bioadhesives to Connect Human Tissues to Long-Term Medical Implants
- New Transcatheter Valve Found Safe and Effective for Treating Aortic Regurgitation
- Minimally Invasive Valve Repair Reduces Hospitalizations in Severe Tricuspid Regurgitation Patients
- Tiny Robotic Tools Powered by Magnetic Fields to Enable Minimally Invasive Brain Surgery
- Magnetic Tweezers Make Robotic Surgery Safer and More Precise
- AI-Powered Surgical Planning Tool Improves Pre-Op Planning
- Novel Sensing System Restores Missing Sense of Touch in Minimally Invasive Surgery
- Headset-Based AR Navigation System Improves EVD Placement
- Higher Electrode Density Improves Epilepsy Surgery by Pinpointing Where Seizures Begin
- Open-Source Tool Optimizes Placement of Visual Brain Implants
- Easy-To-Apply Gel Could Prevent Formation of Post-Surgical Abdominal Adhesions
- Groundbreaking Leadless Pacemaker to Prevent Invasive Surgeries for Children
Channels
Critical Care
view channel
Ingestible Smart Capsule for Chemical Sensing in the Gut Moves Closer to Market
Intestinal gases are associated with several health conditions, including colon cancer, irritable bowel syndrome, and inflammatory bowel disease, and they have the potential to serve as crucial biomarkers... Read more
Novel Cannula Delivery System Enables Targeted Delivery of Imaging Agents and Drugs
Multiphoton microscopy has become an invaluable tool in neuroscience, allowing researchers to observe brain activity in real time with high-resolution imaging. A crucial aspect of many multiphoton microscopy... Read more
Novel Intrabronchial Method Delivers Cell Therapies in Critically Ill Patients on External Lung Support
Until now, administering cell therapies to patients on extracorporeal membrane oxygenation (ECMO)—a life-support system typically used for severe lung failure—has been nearly impossible.... Read morePatient Care
view channel
Portable Biosensor Platform to Reduce Hospital-Acquired Infections
Approximately 4 million patients in the European Union acquire healthcare-associated infections (HAIs) or nosocomial infections each year, with around 37,000 deaths directly resulting from these infections,... Read more
First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds
Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more
Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization
An innovative solution has the capability to transform surgical capacity utilization by targeting the root cause of surgical block time inefficiencies. Fujitsu Limited’s (Tokyo, Japan) Surgical Capacity... Read more
Game-Changing Innovation in Surgical Instrument Sterilization Significantly Improves OR Throughput
A groundbreaking innovation enables hospitals to significantly improve instrument processing time and throughput in operating rooms (ORs) and sterile processing departments. Turbett Surgical, Inc.... Read moreHealth IT
view channel
Printable Molecule-Selective Nanoparticles Enable Mass Production of Wearable Biosensors
The future of medicine is likely to focus on the personalization of healthcare—understanding exactly what an individual requires and delivering the appropriate combination of nutrients, metabolites, and... Read more
Smartwatches Could Detect Congestive Heart Failure
Diagnosing congestive heart failure (CHF) typically requires expensive and time-consuming imaging techniques like echocardiography, also known as cardiac ultrasound. Previously, detecting CHF by analyzing... Read moreBusiness
view channel
Expanded Collaboration to Transform OR Technology Through AI and Automation
The expansion of an existing collaboration between three leading companies aims to develop artificial intelligence (AI)-driven solutions for smart operating rooms with sophisticated monitoring and automation.... Read more