Simple Impedance Measurement Detects Dehydration
By HospiMedica staff writers Posted on 03 Jan 2008 |
A redesigned medical device that monitors a person's hydration level could improve survival odds for people medically at risk from dehydration or congestive heart failure (CHF).
Scientists at the Oak Ridge National Laboratory (ORNL, TN, USA) improved and miniaturized an existing device called The ZOE Fluid Status Monitor, used primarily in home health care applications, in order to improve the product by making it more robust, smaller, less expensive, and capable of remote monitoring. The ZOE device measures thoracic Zo (base impedance)--a measurement of the electric current traveling from the top to the bottom of the thorax. This is accomplished by placing one electrode at the top and another at the bottom of the breastbone. The smaller the resistance (measured in ohms) the more fluid is inside the chest cavity. The normal range for humans is between 19 ohms and 30 ohms; values lower than 19 indicate that a person may be overhydrated, while values exceeding 30 indicate dehydration. A wearable wireless version of the ZOE instrument, ZOEwi, will allow monitoring during activity and is planned for market introduction in 2008. The ZOE is a product of Noninvasive Medical Technologies (Las Vegas, NV, USA).
"Studies have shown that up to 80% of troops become dehydrated while performing their duties, and that's a major concern to the military because the soldiers are not able to perform at peak levels,” said Katy DeMarr, vice president of government relations at Noninvasive Medical Technologies. "Similarly, high school and college athletes would benefit greatly from knowing their hydration levels.”
Dehydration symptoms generally become noticeable after 2% of one's normal water volume has been lost, and include thirst, decreased urine volume, abnormally dark urine, tiredness, lack of tears, headaches, dry mouth, and dizziness when standing due to orthostatic hypertension. As dehydration increases, symptoms worsen. With 10% to 15% fluid loss, muscles may become spastic, skin may shrivel and wrinkle, vision may dim, urination will be greatly reduced and may become painful, and delirium may begin. Losses greater than 15% are usually fatal.
Related Links:
Oak Ridge National Laboratory
Noninvasive Medical Technologies
Scientists at the Oak Ridge National Laboratory (ORNL, TN, USA) improved and miniaturized an existing device called The ZOE Fluid Status Monitor, used primarily in home health care applications, in order to improve the product by making it more robust, smaller, less expensive, and capable of remote monitoring. The ZOE device measures thoracic Zo (base impedance)--a measurement of the electric current traveling from the top to the bottom of the thorax. This is accomplished by placing one electrode at the top and another at the bottom of the breastbone. The smaller the resistance (measured in ohms) the more fluid is inside the chest cavity. The normal range for humans is between 19 ohms and 30 ohms; values lower than 19 indicate that a person may be overhydrated, while values exceeding 30 indicate dehydration. A wearable wireless version of the ZOE instrument, ZOEwi, will allow monitoring during activity and is planned for market introduction in 2008. The ZOE is a product of Noninvasive Medical Technologies (Las Vegas, NV, USA).
"Studies have shown that up to 80% of troops become dehydrated while performing their duties, and that's a major concern to the military because the soldiers are not able to perform at peak levels,” said Katy DeMarr, vice president of government relations at Noninvasive Medical Technologies. "Similarly, high school and college athletes would benefit greatly from knowing their hydration levels.”
Dehydration symptoms generally become noticeable after 2% of one's normal water volume has been lost, and include thirst, decreased urine volume, abnormally dark urine, tiredness, lack of tears, headaches, dry mouth, and dizziness when standing due to orthostatic hypertension. As dehydration increases, symptoms worsen. With 10% to 15% fluid loss, muscles may become spastic, skin may shrivel and wrinkle, vision may dim, urination will be greatly reduced and may become painful, and delirium may begin. Losses greater than 15% are usually fatal.
Related Links:
Oak Ridge National Laboratory
Noninvasive Medical Technologies
Latest Critical Care News
- Powerful AI Risk Assessment Tool Predicts Outcomes in Heart Failure Patients
- Peptide-Based Hydrogels Repair Damaged Organs and Tissues On-The-Spot
- One-Hour Endoscopic Procedure Could Eliminate Need for Insulin for Type 2 Diabetes
- AI Can Prioritize Emergency Department Patients Requiring Urgent Treatment
- AI to Improve Diagnosis of Atrial Fibrillation
- Stretchable Microneedles to Help In Accurate Tracking of Abnormalities and Identifying Rapid Treatment
- Machine Learning Tool Identifies Rare, Undiagnosed Immune Disorders from Patient EHRs
- On-Skin Wearable Bioelectronic Device Paves Way for Intelligent Implants
- First-Of-Its-Kind Dissolvable Stent to Improve Outcomes for Patients with Severe PAD
- AI Brain-Age Estimation Technology Uses EEG Scans to Screen for Degenerative Diseases
- Wheeze-Counting Wearable Device Monitors Patient's Breathing In Real Time
- Wearable Multiplex Biosensors Could Revolutionize COPD Management
- New Low-Energy Defibrillation Method Controls Cardiac Arrhythmias
- New Machine Learning Models Help Predict Heart Disease Risk in Women
- Deep-Learning Model Predicts Arrhythmia 30 Minutes before Onset
- Breakthrough Technology Combines Detection and Treatment of Nerve-Related Disorders in Single Procedure