HospiMedica

Download Mobile App
Recent News AI Critical Care Surgical Techniques Patient Care Health IT Point of Care Business Focus

Magnet Displacement and Pain Seen in Patients with Cochlear Implants Undergoing MRI Scanning

By HospiMedica International staff writers
Posted on 02 Dec 2014
Print article
Pain, discomfort, and magnet displacement were observed in a small medical records review study of patients with cochlear implants (CIs) who underwent magnetic resonance imaging (MRI) scanning.

The study’s findings were published online November 20, 2014, by JAMA Otolaryngology-Head & Neck Surgery. A CI can help patients with severe to profound hearing loss and about 300,000 individuals worldwide have the device. However, undergoing MRI scanning can pose worries for patients with CI because of exposure of the internal magnet to a strong electromagnetic field. There have been earlier reports of adverse events, according to study.

Bo Gyung Kim, MD, PhD, of the Soonchunhyang University College of Medicine (Asan, Republic of Korea), and coauthors reviewed the medical records of 18 patients with CIs who had MRI scans between 2003 and 2014 at one center. Of the patients, 16 underwent MRI in a 1.5-T scanner and two patients had an MRI in a 3.0-T scanner. The MRIs included 12 brain scans and 18 scans of other areas of the body.

Of the 18 patients, 13 completed their MRI scan without complications (25 of 30 scans). Five patients fitted with protective head bandages could not complete their MRI because of pain: one of these patients experienced magnet displacement. Another patient tolerated the pain and discomfort of her third MRI scan, in spite of having gauze bandages, but experienced magnet polarity reversal. The two patients that underwent 3.0-T MRI scanning did so without bandaging and experienced no adverse events or complications (one patient had an MRI of the knee and the other patient, who had an MRI scan of the shoulder, did note that they experienced some discomfort). Hearing-related performance was unaffected in three CI patients who had major adverse events associated with MRI scanning.

“In the present study, however, we found that seven of the 13 patients who had not undergone general anesthesia [seven of 19 MRI scans] experienced discomfort or pain during the MRI scans. Indeed, one patient who had undergone general anesthesia was awakened by pain during the MRI scan and could not complete the MRI. Our data clearly demonstrate that a significant proportion of patients experienced discomfort or pain during the MRI process and were unable to complete the scans. Therefore, in addition to device safety and image quality, patient comfort should be considered when performing MRI procedures,” the authors noted.

In a related commentary, Emanuel Kanal, MD, of the University of Pittsburgh Medical Center (PA, USA), wrote, “Kim et al have reinforced a strong lesson for us all, that what may be considered safe by some may well be unsafe or unacceptable to others. Their reminder to consider not just mere safety but also morbidity and acceptability to the patient, is refreshing indeed. This should be added to our list of considerations prior to determining any risk-benefit assessment and patient scan recommendations regarding exposure of patients with implants to MRI environments.”

Related Links:

Soonchunhyang University College of Medicine


Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Gold Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Multilevel Self-Loading Stretcher
CARRERA XL

Print article

Channels

Critical Care

view channel
Image: The new risk assessment tool determines patient-specific risks of developing unfavorable outcomes with heart failure (Photo courtesy of 123RF)

Powerful AI Risk Assessment Tool Predicts Outcomes in Heart Failure Patients

Heart failure is a serious condition where the heart cannot pump sufficient blood to meet the body's needs, leading to symptoms like fatigue, weakness, and swelling in the legs and feet, and it can ultimately... Read more

Surgical Techniques

view channel
Image: The multi-sensing device can be implanted into blood vessels to help physicians deliver timely treatment (Photo courtesy of IIT)

Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health

Researchers have embarked on a project to develop a multi-sensing device that can be implanted into blood vessels like peripheral veins or arteries to monitor a range of bodily parameters and overall health status.... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more