Hand-Held Probe Measures Bone Strength
By HospiMedica International staff writers Posted on 07 Apr 2015 |
Image: Professor Emeritus Paul Hansma and the OsteoProbe (Photo courtesy of UCSB).
A new device uses reference point indentation (RPI) to measure the mechanical properties of bone at the tissue level.
The OsteoProbe device is a handheld device that uses RPI technology to inspect the bone material’s ability to resist indentation. The output is bone material strength index (BMSi), a figure that represents the ratio of the indentation distance in bone versus a polymathylmethacrylate (PMMA) reference material. The BMSi score represents resistance of the bone to separation of mineralized collagen fibrils. A BMSi of 90 or greater is considered excellent, 80–90 good, 70–80 fair, 60–70 poor, and below 60 is very poor.
A study conducted at the Mayo Clinic (Rochester, MN, USA) demonstrated the device's ability to successfully detect bone quality deterioration in diabetic patients, independent of bone mineral density (BMD). In another study conducted at Leiden University (The Netherlands), the OsteoProbe successfully distinguished between patients with and without fracture, not only in those with osteoporosis but also in those with osteopenia, the precursor to osteoporosis. The OsteoProbe was developed at UC Santa Barbara (UCSB; CA, USA), and is manufactured by ActiveLife Scientific (Santa Barbara, CA, USA).
“Bone fracture is becoming more and more of a serious problem as people live longer,” said Professor Emeritus Paul Hansma, PhD, of the UCSB department of physics. “It's exciting that it's now possible to measure BMSi in living patients and hopefully this can guide physicians in the future in choosing appropriate therapies to prevent bone fracture, especially in elderly people.”
RPI testing uses the location of measurement as the relative displacement reference position. The technique has its origins in the Mohs scale of mineral hardness, in which materials are ranked according to what they can scratch and are, in turn, scratched by. During the course of indentation, a record of the depth of penetration is made, and then the area of the indent is determined using the known geometry of the indentation tip. A record of these values can be plotted to create a load-displacement curve, which can be used to extract more sophisticated mechanical properties of the material.
Related Links:
Mayo Clinic
UC Santa Barbara
ActiveLife Scientific
The OsteoProbe device is a handheld device that uses RPI technology to inspect the bone material’s ability to resist indentation. The output is bone material strength index (BMSi), a figure that represents the ratio of the indentation distance in bone versus a polymathylmethacrylate (PMMA) reference material. The BMSi score represents resistance of the bone to separation of mineralized collagen fibrils. A BMSi of 90 or greater is considered excellent, 80–90 good, 70–80 fair, 60–70 poor, and below 60 is very poor.
A study conducted at the Mayo Clinic (Rochester, MN, USA) demonstrated the device's ability to successfully detect bone quality deterioration in diabetic patients, independent of bone mineral density (BMD). In another study conducted at Leiden University (The Netherlands), the OsteoProbe successfully distinguished between patients with and without fracture, not only in those with osteoporosis but also in those with osteopenia, the precursor to osteoporosis. The OsteoProbe was developed at UC Santa Barbara (UCSB; CA, USA), and is manufactured by ActiveLife Scientific (Santa Barbara, CA, USA).
“Bone fracture is becoming more and more of a serious problem as people live longer,” said Professor Emeritus Paul Hansma, PhD, of the UCSB department of physics. “It's exciting that it's now possible to measure BMSi in living patients and hopefully this can guide physicians in the future in choosing appropriate therapies to prevent bone fracture, especially in elderly people.”
RPI testing uses the location of measurement as the relative displacement reference position. The technique has its origins in the Mohs scale of mineral hardness, in which materials are ranked according to what they can scratch and are, in turn, scratched by. During the course of indentation, a record of the depth of penetration is made, and then the area of the indent is determined using the known geometry of the indentation tip. A record of these values can be plotted to create a load-displacement curve, which can be used to extract more sophisticated mechanical properties of the material.
Related Links:
Mayo Clinic
UC Santa Barbara
ActiveLife Scientific
Latest Critical Care News
- Powerful AI Risk Assessment Tool Predicts Outcomes in Heart Failure Patients
- Peptide-Based Hydrogels Repair Damaged Organs and Tissues On-The-Spot
- One-Hour Endoscopic Procedure Could Eliminate Need for Insulin for Type 2 Diabetes
- AI Can Prioritize Emergency Department Patients Requiring Urgent Treatment
- AI to Improve Diagnosis of Atrial Fibrillation
- Stretchable Microneedles to Help In Accurate Tracking of Abnormalities and Identifying Rapid Treatment
- Machine Learning Tool Identifies Rare, Undiagnosed Immune Disorders from Patient EHRs
- On-Skin Wearable Bioelectronic Device Paves Way for Intelligent Implants
- First-Of-Its-Kind Dissolvable Stent to Improve Outcomes for Patients with Severe PAD
- AI Brain-Age Estimation Technology Uses EEG Scans to Screen for Degenerative Diseases
- Wheeze-Counting Wearable Device Monitors Patient's Breathing In Real Time
- Wearable Multiplex Biosensors Could Revolutionize COPD Management
- New Low-Energy Defibrillation Method Controls Cardiac Arrhythmias
- New Machine Learning Models Help Predict Heart Disease Risk in Women
- Deep-Learning Model Predicts Arrhythmia 30 Minutes before Onset
- Breakthrough Technology Combines Detection and Treatment of Nerve-Related Disorders in Single Procedure