Contamination Sensor may Tackle Catheter Superbugs

By HospiMedica International staff writers
Posted on 04 May 2016
Print article
Image: A visual color change in urine collection bag in response to P. mirabilis infection (Photo courtesy of the University of Bath).
Image: A visual color change in urine collection bag in response to P. mirabilis infection (Photo courtesy of the University of Bath).
A new study describes a novel infection detection sensor coating designed for urinary catheters that could help prevent serious infections in millions of hospital patients worldwide.

Developed by researchers at the University of Bath (United Kingdom) and the University of Brighton (United Kingdom), the dual layered sensor changes the color of a patients urine when Proteus mirabilis biofilms are formed, which the most common cause of catheter blockage. The lower layer is composed of poly(vinyl alcohol) (PVA), which contains a self-quenching carboxyfluorescein dye. This is capped by an upper layer of the pH-responsive polymer microgel poly(methyl methacrylate-co-methacrylic acid) (PMA-MAA).

An elevation in urinary pH dissolves the PMA-MAA layer, releasing the dye to provide a clear visual warning of impending blockage. Evaluation of prototype coatings using a clinically relevant in vitro bladder model system demonstrated that the coatings provide up to 12 hours advance warning of blockage, and are stable both in the absence of infection and in the presence of bacterial species that do not cause catheter blockage. The study was published early online of February 26, 2016, in Biosensors and Bioelectronics.

“Catheter-related infections are a serious problem, especially if the bacteria are resistant to antibiotics. We hope that with this simple to use sensor system we can ultimately make a real difference to patients' lives,” said senior author biophysical chemist Toby Jenkins, PhD, of the University of Brighton. “Our new coating works with existing catheter designs and gives a clear, early visual warning of infection before a catheter is blocked. It could dramatically reduce the number of infections resulting from bacterial blockages.”

Over time bacteria can build a biofilm layer inside the catheter tubing, eventually blocking it. The urine cannot drain and pushes back into the kidneys, where the bacteria can cause kidney failure, systemic infection, and even death. Up to half the people who use catheters suffer long-term problems with blockages caused by bacteria, but there is currently no way to detect them before they cause problems.

Related Links:
University of Bath
University of Brighton
Gold Member
POC Blood Gas Analyzer
Stat Profile Prime Plus
Gold Member
STI Test
Vivalytic Sexually Transmitted Infection (STI) Array
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Oxidized Zirconium Implant Material
OXINIUM

Print article

Channels

Surgical Techniques

view channel
Image: The ProScan AI assisted reading tool is designed to unlock the future of gastroenterology (Photo courtesy of AnX Robotica)

AI Assisted Reading Tool for Small Bowel Video Capsule Endoscopy Detects More Lesions

A revolutionary artificial intelligence (AI) technology that has proven faster and more accurate in diagnosing small bowel bleeding could transform gastrointestinal medicine. AnX Robotica (Plano, TX,... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more