Flow Diverting Stent Helps Contain Cerebrovascular Defects
By HospiMedica International staff writers Posted on 24 Jul 2018 |
Image: The Surpass Streamline Flow Diverter in proximity to an aneurysm (Photo courtesy of Stryker).
An innovative flow diverter embolization device protects susceptible patients from large and giant brain unruptured aneurysms.
The Stryker (Kalamazoo, MI, USA) Surpass Streamline Flow Diverter is a cobalt chromium braided stent that directs blood flow within an intracranial artery away from a weakened blood vessel sac or aneurysm. The high-mesh density of the braid is achieved by increasing the number of braid wires in concert with device diameter; while the 2 mm device has 48 braided wires, the 3 and 4 mm devices have 72 braided wires, and the 5 mm device has 96 wires, providing a more uniform pore density over different sizes.
Filament sizes change from 25 to 36 mm, depending on the device diameter. The increase in wires maintains consistent density across a range of vessel sizes, thereby facilitating reliable and consistent occlusion of the aneurysm over time, and helping to reduce the risk of a future rupture. In addition, the braid angle is designed to prevent unwanted changes in mesh density around curves and to minimize foreshortening. The Surpass Streamline Flow Diverter is loaded within a 3.7-Fr distal catheter with a pusher catheter and accepts a 0.014-inch micro-guidewire.
Surpass Streamline can be positioned using the Surpass delivery system, designed for consistent deployment; the Halo delivery system, which provides atraumatic access to distal vasculature using an intermediate catheter, improving stent fit and climbing performance; or the Streamline delivery system, which allows it to be repositioned distally or proximally, and to be redeployed until precise placement and enhanced vessel apposition are achieved.
“Surpass Streamline is the first flow diverter indicated for large and giant posterior communicating artery aneurysms; these unruptured aneurysms are more challenging, due to their location and surrounding anatomy,” said professor of radiology and neurological surgery Philip Meyers, MD, of New York Presbyterian/Columbia University Medical Center (NY, USA). “The stent is designed to reliably open and provide consistent mesh density across the neck of the aneurysm to aid in aneurysm occlusion while maintaining perforator artery patency.”
While originally indicated for wide-necked or fusiform aneurysms from the petrous segment to the clinoid segment of the internal carotid artery (ICA), flow diversion today is being more broadly applied to small aneurysms, anterior cerebral artery aneurysms, recurrent aneurysms, and other endoluminal and intra-saccular defects.
The Stryker (Kalamazoo, MI, USA) Surpass Streamline Flow Diverter is a cobalt chromium braided stent that directs blood flow within an intracranial artery away from a weakened blood vessel sac or aneurysm. The high-mesh density of the braid is achieved by increasing the number of braid wires in concert with device diameter; while the 2 mm device has 48 braided wires, the 3 and 4 mm devices have 72 braided wires, and the 5 mm device has 96 wires, providing a more uniform pore density over different sizes.
Filament sizes change from 25 to 36 mm, depending on the device diameter. The increase in wires maintains consistent density across a range of vessel sizes, thereby facilitating reliable and consistent occlusion of the aneurysm over time, and helping to reduce the risk of a future rupture. In addition, the braid angle is designed to prevent unwanted changes in mesh density around curves and to minimize foreshortening. The Surpass Streamline Flow Diverter is loaded within a 3.7-Fr distal catheter with a pusher catheter and accepts a 0.014-inch micro-guidewire.
Surpass Streamline can be positioned using the Surpass delivery system, designed for consistent deployment; the Halo delivery system, which provides atraumatic access to distal vasculature using an intermediate catheter, improving stent fit and climbing performance; or the Streamline delivery system, which allows it to be repositioned distally or proximally, and to be redeployed until precise placement and enhanced vessel apposition are achieved.
“Surpass Streamline is the first flow diverter indicated for large and giant posterior communicating artery aneurysms; these unruptured aneurysms are more challenging, due to their location and surrounding anatomy,” said professor of radiology and neurological surgery Philip Meyers, MD, of New York Presbyterian/Columbia University Medical Center (NY, USA). “The stent is designed to reliably open and provide consistent mesh density across the neck of the aneurysm to aid in aneurysm occlusion while maintaining perforator artery patency.”
While originally indicated for wide-necked or fusiform aneurysms from the petrous segment to the clinoid segment of the internal carotid artery (ICA), flow diversion today is being more broadly applied to small aneurysms, anterior cerebral artery aneurysms, recurrent aneurysms, and other endoluminal and intra-saccular defects.
Latest Surgical Techniques News
- Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health
- Tiny Robots Made Out Of Carbon Could Conduct Colonoscopy, Pelvic Exam or Blood Test
- Miniaturized Ultrasonic Scalpel Enables Faster and Safer Robotic-Assisted Surgery
- AI Assisted Reading Tool for Small Bowel Video Capsule Endoscopy Detects More Lesions
- First-Ever Contact Force Pulsed Field Ablation System to Transform Treatment of Ventricular Arrhythmias
- Caterpillar Robot with Built-In Steering System Crawls Easily Through Loops and Bends
- Tiny Wraparound Electronic Implants to Revolutionize Treatment of Spinal Cord Injuries
- Small, Implantable Cardiac Pump to Help Children Awaiting Heart Transplant
- Gastrointestinal Imaging Capsule a Game-Changer in Esophagus Surveillance and Treatment
- World’s Smallest Laser Probe for Brain Procedures Facilitates Ablation of Full Range of Targets
- Artificial Intelligence Broadens Diagnostic Abilities of Conventional Coronary Angiography
- AI-Powered Surgical Visualization Tool Supports Surgeons' Visual Recognition in Real Time
- Cutting-Edge Robotic Bronchial Endoscopic System Provides Prompt Intervention during Emergencies
- Handheld Device for Fluorescence-Guided Surgery a Game Changer for Removal of High-Grade Glioma Brain Tumors
- Porous Gel Sponge Facilitates Rapid Hemostasis and Wound Healing
- Novel Rigid Endoscope System Enables Deep Tissue Imaging During Surgery