We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

HospiMedica

Download Mobile App
Recent News AI Critical Care Surgical Techniques Patient Care Health IT Point of Care Business Focus

Retropubic Sling Surgery Superior for Treating SUI

By HospiMedica International staff writers
Posted on 23 Jul 2019
Print article
Image: A comparison of the retropubic and transobturator sling procedures (Photo courtesy of the Mayo Clinic).
Image: A comparison of the retropubic and transobturator sling procedures (Photo courtesy of the Mayo Clinic).
Retropubic sling procedures for stress urinary incontinence (SUI) demonstrate better long-term results than transobturator sling surgery, according to a new study.

Researchers at the Mayo Clinic (Rochester, MN, USA), Case Western Reserve University (CWRU; Cleveland, OH, USA), and other institutions conducted a retrospective cohort study of 1,881 women who underwent midurethral sling procedures for primary SUI at the Mayo Clinic between 2002 and 2012. The primary outcome was defined as reoperation for recurrent SUI, with secondary outcomes including intraoperative complications and mesh-related complications requiring reoperation after the index sling procedure.

In all, 1,551 women underwent a retropubic sling and 330 underwent a transobturator sling procedure. The results showed that reoperations within an eight-year period were 11.2% following transobturator sling surgery, compared to 5.2% after a retropubic sling procedure. On the other hand, women in the retropubic group had a significantly higher rate of intraoperative complications, mostly due to bladder perforation. The cumulative incidence of sling revision for urinary retention plateaued at 3.2% and 0.4% by 5 years in the two groups, respectively. The study was published on July 9, 2019, in Obstetrics and Gynecology.

“The failure rate for the transobturator procedure was even higher among women who had the sling combined with vaginal prolapse repair. These findings would suggest that the retropubic procedure has better long-term results compared to the transobturator sling,” said lead author urogynecologist Emanuel Trabuco, MD, MSc. “We're hopeful that the findings in this study will encourage women to talk to a provider about the surgical and nonsurgical options to treat their conditions, which can greatly affect a woman's daily activities.”

SUI is a loss of bladder control or involuntary loss of urine when coughing, laughing, sneezing, or during heavy lifting, or simply getting up from a chair. It is the most common type of incontinence suffered by women, especially older women and those who have given birth. Other causes for SUI in women include weak pelvic muscles or a weak sphincter muscle, chronic coughing, smoking and obesity.

Related Links:
Mayo Clinic
Case Western Reserve University

Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Gold Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Baby Warmer
THERMOCARE Convenience

Print article

Channels

Critical Care

view channel
Image: The stretchable microneedle electrode arrays (Photo courtesy of Zhao Research Group)

Stretchable Microneedles to Help In Accurate Tracking of Abnormalities and Identifying Rapid Treatment

The field of personalized medicine is transforming rapidly, with advancements like wearable devices and home testing kits making it increasingly easy to monitor a wide range of health metrics, from heart... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more