New Method Improves Accuracy of NIRF-IVUS Measurements in Cardiovascular Imaging

By HospiMedica International staff writers
Posted on 17 Apr 2023
Print article
Image: Fluorescence-coated guidewire aids in accurate estimation of blood attenuation during intravascular procedures (Photo courtesy of TUM)
Image: Fluorescence-coated guidewire aids in accurate estimation of blood attenuation during intravascular procedures (Photo courtesy of TUM)

Intravascular ultrasound (IVUS) allows cardiologists to capture images of blood vessels' interiors using a slim ultrasound probe, which can then be used to assess issues like arterial thickening due to fat or plaque accumulation. Near-infrared fluorescence (NIRF) imaging is employed alongside IVUS for a more comprehensive evaluation of blood vessels. NIRF relies on fluorescent agents that highlight biological processes within the body. When injected into the bloodstream, these agents bind to specific pathology-related compounds on vessel walls, such as proteins or nucleic acids. The resulting fluorescence signals are combined with IVUS images for enhanced accuracy. However, during NIRF-IVUS measurements, the distance between the NIRF detector and the blood vessel wall continually changes. This presents a challenge, as blood attenuates the fluorescence signals' intensity, and the "amount" of blood between the NIRF detector and the vessel wall constantly varies.

A team of researchers led by the Technical University of Munich (TUM, Munich, Germany) has come up with an innovative solution to this problem. In a study, the team created a new technique to measure blood's fluorescence attenuation using a "guidewire" that moves the NIRF-IVUS probe. The concept is based on the constant visibility of the guidewire to the NIRF probe. By coating the guidewire with a known concentration of fluorescent particles, the guidewire signal offers an indirect measure of blood attenuation in the current image. The distance between the NIRF probe and the guidewire, as well as the blood vessel wall, is determined via IVUS, allowing for the calculation of a correction factor for the fluorescence signal measured at the blood vessel wall after a simple calibration procedure.

The team tested their technique in a clinical model using a small NIRF-IVUS system from a previous study and conducted experiments on capillary phantoms, which mimic small blood vessels' properties. They observed a 4.5-fold improvement over uncorrected NIRF signals and <11% errors for target signals, showing great promise. The correction method also maintained a mean accuracy of 70% in tissue experiments. These figures are significantly better than those achieved by other correction methods that use average attenuation factors instead of calculating them for each frame and precise probe-to-vessel distances measured via IVUS. The researchers believe that incorporating their technique into clinical practice should be relatively straightforward since no major modifications to existing equipment are necessary. With the appropriate coatings, the guidewire can serve as a reference standard for other intravascular fluorescence imaging modalities and optical methods beyond fluorescence.

“This new method for correcting intravascular NIRF signals is simple and accurate and could pave the way for in vivo studies and eventual clinical translation,” said Brian Pogue, Professor of Medical Physics at the University of Wisconsin-Madison.

Related Links:
TUM 

Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Ultra Low Floor Level Bed
Solite Pro

Print article

Channels

Critical Care

view channel
Image: The new risk assessment tool determines patient-specific risks of developing unfavorable outcomes with heart failure (Photo courtesy of 123RF)

Powerful AI Risk Assessment Tool Predicts Outcomes in Heart Failure Patients

Heart failure is a serious condition where the heart cannot pump sufficient blood to meet the body's needs, leading to symptoms like fatigue, weakness, and swelling in the legs and feet, and it can ultimately... Read more

Surgical Techniques

view channel
Image: The multi-sensing device can be implanted into blood vessels to help physicians deliver timely treatment (Photo courtesy of IIT)

Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health

Researchers have embarked on a project to develop a multi-sensing device that can be implanted into blood vessels like peripheral veins or arteries to monitor a range of bodily parameters and overall health status.... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing