Reloadable Fixation Device Assists Laparoscopic Hernia Repair
By HospiMedica International staff writers Posted on 11 Nov 2014 |
An articulating fixation device delivers superior access, stronger fixation, and lower cost of care for minimally invasive hernia repair.
The ReliaTack system provides surgeons with greater access to weak spots within the abdominal wall thanks to an adjustable articulation of up to 65 degrees, enabling them to more securely place tacks perpendicular to the mesh, minimize mesh shift, and potentially eliminate contralateral ports. The system is provided with proprietary 5.1 mm long absorbable screw-like tacks constructed of poly lactic-co-glycolic acid (PLGA), an absorbable synthetic polyester copolymer that is dyed violet for enhanced visibility.
The tacks offer twice the strength staple fixation devices, and are available in interchangeable reload sets that are packaged together with the handle. The device can accommodate standard 5- or 10- PGLA tack reloads, reloaded and fired for a total of 60 tacks in a single procedure. The PGLA tacks degrade and are absorbed by hydrolysis to glycolic acid and lactic acid, which are then metabolized by the body. PGLA absorption is essentially completed prior to one year. The ReliaTack system is a product of Covidien (Dublin, Ireland), and had been approved by the US Food and Drug Administration (FDA).
“Developed with valuable input from surgeons, the ReliaTack device, combined with our recently-launched Symbotex composite mesh, benefits patients while helping drive greater operating room efficiency and economic benefits,” said Rob Claypoole, vice president and general manager of Hernia at Covidien. “The ReliaTack fixation device overcomes numerous physical and ergonomic challenges in ventral hernia repair by allowing a wide variety of angles to more effectively position and secure hernia mesh.”
Laparoscopic ventral hernia repair involves the placement of a mesh inside the abdomen, without abdominal wall reconstruction; the mesh is fixed with sutures, staples, or tacks. The recurrence rate of laparoscopic repair is reported as equal (or less) than an open approach. On the other hand, the laparoscopic approach has been criticized for not resecting the hernia sac and not restoring the anatomy, resulting in persistence of abdominal bulging and an abdominal wall that is mechanically unstable and has uncoordinated muscles. In addition, placement of a mesh over the defect leads to seroma formation in a large number of patients.
Related Links:
Covidien
The ReliaTack system provides surgeons with greater access to weak spots within the abdominal wall thanks to an adjustable articulation of up to 65 degrees, enabling them to more securely place tacks perpendicular to the mesh, minimize mesh shift, and potentially eliminate contralateral ports. The system is provided with proprietary 5.1 mm long absorbable screw-like tacks constructed of poly lactic-co-glycolic acid (PLGA), an absorbable synthetic polyester copolymer that is dyed violet for enhanced visibility.
The tacks offer twice the strength staple fixation devices, and are available in interchangeable reload sets that are packaged together with the handle. The device can accommodate standard 5- or 10- PGLA tack reloads, reloaded and fired for a total of 60 tacks in a single procedure. The PGLA tacks degrade and are absorbed by hydrolysis to glycolic acid and lactic acid, which are then metabolized by the body. PGLA absorption is essentially completed prior to one year. The ReliaTack system is a product of Covidien (Dublin, Ireland), and had been approved by the US Food and Drug Administration (FDA).
“Developed with valuable input from surgeons, the ReliaTack device, combined with our recently-launched Symbotex composite mesh, benefits patients while helping drive greater operating room efficiency and economic benefits,” said Rob Claypoole, vice president and general manager of Hernia at Covidien. “The ReliaTack fixation device overcomes numerous physical and ergonomic challenges in ventral hernia repair by allowing a wide variety of angles to more effectively position and secure hernia mesh.”
Laparoscopic ventral hernia repair involves the placement of a mesh inside the abdomen, without abdominal wall reconstruction; the mesh is fixed with sutures, staples, or tacks. The recurrence rate of laparoscopic repair is reported as equal (or less) than an open approach. On the other hand, the laparoscopic approach has been criticized for not resecting the hernia sac and not restoring the anatomy, resulting in persistence of abdominal bulging and an abdominal wall that is mechanically unstable and has uncoordinated muscles. In addition, placement of a mesh over the defect leads to seroma formation in a large number of patients.
Related Links:
Covidien
Read the full article by registering today, it's FREE!
Register now for FREE to HospiMedica.com and get complete access to news and events that shape the world of Hospital Medicine.
- Free digital version edition of HospiMedica International sent by email on regular basis
- Free print version of HospiMedica International magazine (available only outside USA and Canada).
- Free and unlimited access to back issues of HospiMedica International in digital format
- Free HospiMedica International Newsletter sent every week containing the latest news
- Free breaking news sent via email
- Free access to Events Calendar
- Free access to LinkXpress new product services
- REGISTRATION IS FREE AND EASY!
Sign in: Registered website members
Sign in: Registered magazine subscribers
Latest Surgical Techniques News
- Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health
- Tiny Robots Made Out Of Carbon Could Conduct Colonoscopy, Pelvic Exam or Blood Test
- Miniaturized Ultrasonic Scalpel Enables Faster and Safer Robotic-Assisted Surgery
- AI Assisted Reading Tool for Small Bowel Video Capsule Endoscopy Detects More Lesions
- First-Ever Contact Force Pulsed Field Ablation System to Transform Treatment of Ventricular Arrhythmias
- Caterpillar Robot with Built-In Steering System Crawls Easily Through Loops and Bends
- Tiny Wraparound Electronic Implants to Revolutionize Treatment of Spinal Cord Injuries
- Small, Implantable Cardiac Pump to Help Children Awaiting Heart Transplant
- Gastrointestinal Imaging Capsule a Game-Changer in Esophagus Surveillance and Treatment
- World’s Smallest Laser Probe for Brain Procedures Facilitates Ablation of Full Range of Targets
- Artificial Intelligence Broadens Diagnostic Abilities of Conventional Coronary Angiography
- AI-Powered Surgical Visualization Tool Supports Surgeons' Visual Recognition in Real Time
- Cutting-Edge Robotic Bronchial Endoscopic System Provides Prompt Intervention during Emergencies
- Handheld Device for Fluorescence-Guided Surgery a Game Changer for Removal of High-Grade Glioma Brain Tumors
- Porous Gel Sponge Facilitates Rapid Hemostasis and Wound Healing
- Novel Rigid Endoscope System Enables Deep Tissue Imaging During Surgery