Filter System Protects Against Catheterization Emboli
By HospiMedica International staff writers Posted on 14 Jan 2015 |
Image: The Wirion distal embolic filter protection system (Photo courtesy of Allium Medical).
A novel distal embolic protection system allows physicians to navigate challenging anatomies with confidence during minimally invasive catheterization procedures.
The Wirion filter system is a one-size embolic protection device that allows the physician to use any 0.014" guidewire throughout the entire procedure, covering vessels ranging between 3.5–6 mm in diameter. At the heart of the system is proprietary deliver, lock, and deploy (DLD) technology that enables in-situ locking of cardiovascular devices onto a standard guide wire, without affecting procedure workflow. The physician can thus lock the uniform, 120 μm pore filter anywhere along the wire, providing continuous blood flow while maintaining capture efficiency and optimal side branch protection, and without compromising wire support and stability.
The mechanism is remotely activated from the proximal end, locking and deploying the stand-alone filter onto the independent guide wire, creating an in-situ embolic protection unit. Once the stent procedure is completed, the filter is removed using a retrieval catheter which employs retractable tip technology, ensuring smooth deliverability across the stented area, particularly in tortuous anatomies and open cell design stents. The Wirion filter system is a product of Allium Medical (Caesarea, Israel), and has received the European Community CE marking of approval.
“The ability to cross the lesion over the guide wire of choice and then deploy the filter in place creates a unique, natural and appealing advantage for all indications,” concluded Dierk Scheinert, MD, who led the clinical trials of the device at the University of Leipzig (Germany) Heart Center. “Clinical outcomes appear to be favorable and the role of this new device in carotid artery stenting needs to be further confirmed in a larger patient population.”
During cardiovascular procedures, debris from the aortic valve, ascending aorta, and other sources may embolize and cause cerebral infarction. The cerebral damage may not be clinically evident after cardiovascular procedures and can take months or years for symptoms to manifest, often presenting as devastating stroke, dementia, and cognitive decline.
Related Links:
Allium Medical
University of Leipzig
The Wirion filter system is a one-size embolic protection device that allows the physician to use any 0.014" guidewire throughout the entire procedure, covering vessels ranging between 3.5–6 mm in diameter. At the heart of the system is proprietary deliver, lock, and deploy (DLD) technology that enables in-situ locking of cardiovascular devices onto a standard guide wire, without affecting procedure workflow. The physician can thus lock the uniform, 120 μm pore filter anywhere along the wire, providing continuous blood flow while maintaining capture efficiency and optimal side branch protection, and without compromising wire support and stability.
The mechanism is remotely activated from the proximal end, locking and deploying the stand-alone filter onto the independent guide wire, creating an in-situ embolic protection unit. Once the stent procedure is completed, the filter is removed using a retrieval catheter which employs retractable tip technology, ensuring smooth deliverability across the stented area, particularly in tortuous anatomies and open cell design stents. The Wirion filter system is a product of Allium Medical (Caesarea, Israel), and has received the European Community CE marking of approval.
“The ability to cross the lesion over the guide wire of choice and then deploy the filter in place creates a unique, natural and appealing advantage for all indications,” concluded Dierk Scheinert, MD, who led the clinical trials of the device at the University of Leipzig (Germany) Heart Center. “Clinical outcomes appear to be favorable and the role of this new device in carotid artery stenting needs to be further confirmed in a larger patient population.”
During cardiovascular procedures, debris from the aortic valve, ascending aorta, and other sources may embolize and cause cerebral infarction. The cerebral damage may not be clinically evident after cardiovascular procedures and can take months or years for symptoms to manifest, often presenting as devastating stroke, dementia, and cognitive decline.
Related Links:
Allium Medical
University of Leipzig
Latest Surgical Techniques News
- Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health
- Tiny Robots Made Out Of Carbon Could Conduct Colonoscopy, Pelvic Exam or Blood Test
- Miniaturized Ultrasonic Scalpel Enables Faster and Safer Robotic-Assisted Surgery
- AI Assisted Reading Tool for Small Bowel Video Capsule Endoscopy Detects More Lesions
- First-Ever Contact Force Pulsed Field Ablation System to Transform Treatment of Ventricular Arrhythmias
- Caterpillar Robot with Built-In Steering System Crawls Easily Through Loops and Bends
- Tiny Wraparound Electronic Implants to Revolutionize Treatment of Spinal Cord Injuries
- Small, Implantable Cardiac Pump to Help Children Awaiting Heart Transplant
- Gastrointestinal Imaging Capsule a Game-Changer in Esophagus Surveillance and Treatment
- World’s Smallest Laser Probe for Brain Procedures Facilitates Ablation of Full Range of Targets
- Artificial Intelligence Broadens Diagnostic Abilities of Conventional Coronary Angiography
- AI-Powered Surgical Visualization Tool Supports Surgeons' Visual Recognition in Real Time
- Cutting-Edge Robotic Bronchial Endoscopic System Provides Prompt Intervention during Emergencies
- Handheld Device for Fluorescence-Guided Surgery a Game Changer for Removal of High-Grade Glioma Brain Tumors
- Porous Gel Sponge Facilitates Rapid Hemostasis and Wound Healing
- Novel Rigid Endoscope System Enables Deep Tissue Imaging During Surgery