Cardiac Closure Device Reduces Stroke Risk
By HospiMedica International staff writers Posted on 05 Apr 2015 |
An innovative left atrial appendage (LAA) closure device assists high-risk patients with non-valvular atrial fibrillation (AF) who are seeking an alternative to long-term warfarin therapy.
The Watchman LAA closure system consists of a delivery catheter, an access sheath that serves as a conduit for the delivery catheter, and the LAA closure device itself, which is permanently implanted at or slightly distal to the ostium of the LAA, blocking it off to prevent thrombus embolization. The Watchman LAA is made of a nitinol frame with a polyethylene terephthalate (PET) membrane cap, and is available in five diameters (21, 24, 27, 30, and 33 mm); 10 active fixation anchors provide stability and retention. The access sheath is available in either a double or single curve distal tip.
A transesophageal echocardiogram (TEE) is first performed to determine device size. The placement procedure is performed in a catheterization laboratory, using standard transseptal technique. Once the inter-atrial septum is crossed, the access sheath is advanced over a guidewire into the left atrium and onto the distal portion of the LAA over a pigtail catheter. The Watchman is then advanced under fluoroscopic guidance and deployed into the LAA. The Watchman LAA closure device is a product of Boston Scientific (Natick, MA, USA), and has been approved by the US Food and Drug Administration (FDA).
“Boston Scientific is proud to offer this potentially life-changing stroke risk treatment option to high-risk patients with AF who have a reason to seek a non-drug alternative to warfarin,” said Joe Fitzgerald, executive vice president and president of rhythm management at Boston Scientific. “FDA approval of the Watchman device is another example of Boston Scientific delivering on its commitment to bring meaningful innovations to patient care.”
“The Watchman device is a breakthrough treatment providing those patients who are suitable for warfarin with an implant-based alternative to long-term warfarin therapy while still reducing the risk of stroke,” said Vivek Reddy, MD, director of the cardiac arrhythmia service at Mount Sinai Medical Center (Miami, FL, USA). “We know that up to 40% of patients who are eligible for oral anticoagulation do not take it for numerous reasons, highlighting the need for additional treatment options.”
The LAA is a small, ear-shaped sac in the muscle wall of the left atrium. In normal hearts, the heart contracts with each heartbeat, and the blood in the left atrium and LAA is squeezed out into the left ventricle. When a patient has AF, the chaotic impulses do not give the atria time to contract, and blood collects and can form clots in the LAA and atria. The LAA is thought to be the source of more than 90% of stroke-causing blood clots that come from the heart in non-valvular AF patients.
Related Links:
Boston Scientific
Mount Sinai Medical Center
The Watchman LAA closure system consists of a delivery catheter, an access sheath that serves as a conduit for the delivery catheter, and the LAA closure device itself, which is permanently implanted at or slightly distal to the ostium of the LAA, blocking it off to prevent thrombus embolization. The Watchman LAA is made of a nitinol frame with a polyethylene terephthalate (PET) membrane cap, and is available in five diameters (21, 24, 27, 30, and 33 mm); 10 active fixation anchors provide stability and retention. The access sheath is available in either a double or single curve distal tip.
A transesophageal echocardiogram (TEE) is first performed to determine device size. The placement procedure is performed in a catheterization laboratory, using standard transseptal technique. Once the inter-atrial septum is crossed, the access sheath is advanced over a guidewire into the left atrium and onto the distal portion of the LAA over a pigtail catheter. The Watchman is then advanced under fluoroscopic guidance and deployed into the LAA. The Watchman LAA closure device is a product of Boston Scientific (Natick, MA, USA), and has been approved by the US Food and Drug Administration (FDA).
“Boston Scientific is proud to offer this potentially life-changing stroke risk treatment option to high-risk patients with AF who have a reason to seek a non-drug alternative to warfarin,” said Joe Fitzgerald, executive vice president and president of rhythm management at Boston Scientific. “FDA approval of the Watchman device is another example of Boston Scientific delivering on its commitment to bring meaningful innovations to patient care.”
“The Watchman device is a breakthrough treatment providing those patients who are suitable for warfarin with an implant-based alternative to long-term warfarin therapy while still reducing the risk of stroke,” said Vivek Reddy, MD, director of the cardiac arrhythmia service at Mount Sinai Medical Center (Miami, FL, USA). “We know that up to 40% of patients who are eligible for oral anticoagulation do not take it for numerous reasons, highlighting the need for additional treatment options.”
The LAA is a small, ear-shaped sac in the muscle wall of the left atrium. In normal hearts, the heart contracts with each heartbeat, and the blood in the left atrium and LAA is squeezed out into the left ventricle. When a patient has AF, the chaotic impulses do not give the atria time to contract, and blood collects and can form clots in the LAA and atria. The LAA is thought to be the source of more than 90% of stroke-causing blood clots that come from the heart in non-valvular AF patients.
Related Links:
Boston Scientific
Mount Sinai Medical Center
Read the full article by registering today, it's FREE!
Register now for FREE to HospiMedica.com and get complete access to news and events that shape the world of Hospital Medicine.
- Free digital version edition of HospiMedica International sent by email on regular basis
- Free print version of HospiMedica International magazine (available only outside USA and Canada).
- Free and unlimited access to back issues of HospiMedica International in digital format
- Free HospiMedica International Newsletter sent every week containing the latest news
- Free breaking news sent via email
- Free access to Events Calendar
- Free access to LinkXpress new product services
- REGISTRATION IS FREE AND EASY!
Sign in: Registered website members
Sign in: Registered magazine subscribers
Latest Surgical Techniques News
- AI Assisted Reading Tool for Small Bowel Video Capsule Endoscopy Detects More Lesions
- First-Ever Contact Force Pulsed Field Ablation System to Transform Treatment of Ventricular Arrhythmias
- Caterpillar Robot with Built-In Steering System Crawls Easily Through Loops and Bends
- Tiny Wraparound Electronic Implants to Revolutionize Treatment of Spinal Cord Injuries
- Small, Implantable Cardiac Pump to Help Children Awaiting Heart Transplant
- Gastrointestinal Imaging Capsule a Game-Changer in Esophagus Surveillance and Treatment
- World’s Smallest Laser Probe for Brain Procedures Facilitates Ablation of Full Range of Targets
- Artificial Intelligence Broadens Diagnostic Abilities of Conventional Coronary Angiography
- AI-Powered Surgical Visualization Tool Supports Surgeons' Visual Recognition in Real Time
- Cutting-Edge Robotic Bronchial Endoscopic System Provides Prompt Intervention during Emergencies
- Handheld Device for Fluorescence-Guided Surgery a Game Changer for Removal of High-Grade Glioma Brain Tumors
- Porous Gel Sponge Facilitates Rapid Hemostasis and Wound Healing
- Novel Rigid Endoscope System Enables Deep Tissue Imaging During Surgery
- Robotic Nerve ‘Cuffs’ Could Treat Various Neurological Conditions
- Flexible Microdisplay Visualizes Brain Activity in Real-Time To Guide Neurosurgeons
- Next-Gen Computer Assisted Vacuum Thrombectomy Technology Rapidly Removes Blood Clots