Endoscopic Ablation System Treats Paroxysmal Atrial Fibrillation
By HospiMedica International staff writers Posted on 21 Apr 2016 |
Image: The HeartLight endoscopic ablation system (Photo courtesy of CardioFocus).
Innovative catheter ablation technology allows clinicians to visually direct laser energy for achieving durable pulmonary vein isolation (PVI) in the treatment of atrial fibrillation (AF).
The HeartLight Endoscopic Ablation System is intended for the treatment of drug refractory recurrent symptomatic paroxysmal AF. The system is based on a near infrared (NIR) laser light and a deflectable sheath that provides efficient transseptal access for ablation of all four pulmonary veins. The sheath is first used to transport a catheter to the vicinity of the vein using fluoroscopy, whereupon the compliant balloon is inflated. Once tissue contact is achieved, an integral micro-endoscope is used to visualize the placement of the balloon relative to the ostium of the vein.
The physician then uses the endoscopic image acquired by direct visualization to determine placement of each arc of NIR laser light, in order to place overlapping arcs into the atrial wall around each vein. The endoscope also provides feedback on progress obtained in achieving vein isolation via a dynamic view of the developing lesions on the cardiac tissue. The scar tissue creates a conduction block with just several 20-30 second energy deliveries. The HeartLight system is a product of CardioFocus (Marlborough, MA, USA), and has been approved by the US Food and Drug Administration (FDA).
“Based on our experience in the CardioFocus pivotal study and the successful results from the European Union, I am confident that this new laser balloon catheter will offer our patients an outstanding treatment option for atrial fibrillation,” said Frank Cuoco, MD, of the Medical University of South Carolina (Charleston, SC, USA). “The flexibility of the compliant balloon, which is intuitive to use under direct visual guidance, is one of its primary appeals. I found the learning curve to be very short.”
PVI is a catheter ablation technique developed to prevent focal triggers in the pulmonary veins from initiating episodes of AF. Although the procedure initially involved focal ablation with a catheter directly in the pulmonary veins, applying ablation energy at their junction with the left atrium is more effective. The PVI procedure is most suitable for patients whose recurring symptomatic episodes of AF that have not been suppressed by anti-arrhythmic drugs, or who do not wish to take long- term anti-arrhythmic or anticoagulation medications.
Related Links:
CardioFocus
The HeartLight Endoscopic Ablation System is intended for the treatment of drug refractory recurrent symptomatic paroxysmal AF. The system is based on a near infrared (NIR) laser light and a deflectable sheath that provides efficient transseptal access for ablation of all four pulmonary veins. The sheath is first used to transport a catheter to the vicinity of the vein using fluoroscopy, whereupon the compliant balloon is inflated. Once tissue contact is achieved, an integral micro-endoscope is used to visualize the placement of the balloon relative to the ostium of the vein.
The physician then uses the endoscopic image acquired by direct visualization to determine placement of each arc of NIR laser light, in order to place overlapping arcs into the atrial wall around each vein. The endoscope also provides feedback on progress obtained in achieving vein isolation via a dynamic view of the developing lesions on the cardiac tissue. The scar tissue creates a conduction block with just several 20-30 second energy deliveries. The HeartLight system is a product of CardioFocus (Marlborough, MA, USA), and has been approved by the US Food and Drug Administration (FDA).
“Based on our experience in the CardioFocus pivotal study and the successful results from the European Union, I am confident that this new laser balloon catheter will offer our patients an outstanding treatment option for atrial fibrillation,” said Frank Cuoco, MD, of the Medical University of South Carolina (Charleston, SC, USA). “The flexibility of the compliant balloon, which is intuitive to use under direct visual guidance, is one of its primary appeals. I found the learning curve to be very short.”
PVI is a catheter ablation technique developed to prevent focal triggers in the pulmonary veins from initiating episodes of AF. Although the procedure initially involved focal ablation with a catheter directly in the pulmonary veins, applying ablation energy at their junction with the left atrium is more effective. The PVI procedure is most suitable for patients whose recurring symptomatic episodes of AF that have not been suppressed by anti-arrhythmic drugs, or who do not wish to take long- term anti-arrhythmic or anticoagulation medications.
Related Links:
CardioFocus
Latest Surgical Techniques News
- Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health
- Tiny Robots Made Out Of Carbon Could Conduct Colonoscopy, Pelvic Exam or Blood Test
- Miniaturized Ultrasonic Scalpel Enables Faster and Safer Robotic-Assisted Surgery
- AI Assisted Reading Tool for Small Bowel Video Capsule Endoscopy Detects More Lesions
- First-Ever Contact Force Pulsed Field Ablation System to Transform Treatment of Ventricular Arrhythmias
- Caterpillar Robot with Built-In Steering System Crawls Easily Through Loops and Bends
- Tiny Wraparound Electronic Implants to Revolutionize Treatment of Spinal Cord Injuries
- Small, Implantable Cardiac Pump to Help Children Awaiting Heart Transplant
- Gastrointestinal Imaging Capsule a Game-Changer in Esophagus Surveillance and Treatment
- World’s Smallest Laser Probe for Brain Procedures Facilitates Ablation of Full Range of Targets
- Artificial Intelligence Broadens Diagnostic Abilities of Conventional Coronary Angiography
- AI-Powered Surgical Visualization Tool Supports Surgeons' Visual Recognition in Real Time
- Cutting-Edge Robotic Bronchial Endoscopic System Provides Prompt Intervention during Emergencies
- Handheld Device for Fluorescence-Guided Surgery a Game Changer for Removal of High-Grade Glioma Brain Tumors
- Porous Gel Sponge Facilitates Rapid Hemostasis and Wound Healing
- Novel Rigid Endoscope System Enables Deep Tissue Imaging During Surgery