Increased Thrombosis Casts Doubt on Bioresorbable Scaffolds

By HospiMedica International staff writers
Posted on 18 Apr 2017
Print article
Image: The Absorb BVS, the stent used in the study (Photo courtesy of Abbott Vascular).
Image: The Absorb BVS, the stent used in the study (Photo courtesy of Abbott Vascular).
A new study reveals that bioresorbable scaffolds are associated with a fivefold higher incidence of thrombosis than a metallic stent following routine percutaneous coronary intervention (PCI).

Researchers at Academic Medical Center, Albert Schweitzer Hospital conducted an investigator-initiated, randomized trial that randomly assigned 1,845 patients undergoing PCI to receive either a everolimus-eluting bioresorbable vascular scaffold (BVS; 924 patients) or a everolimus-eluting metallic stent (921 patients). The primary end point was target-vessel failure, a composite of cardiac death, target-vessel myocardial infarction (MI), or target-vessel revascularization. Median follow-up was 707 days.

The results showed that target-vessel failure occurred in 11.7% of patients in the BVS group and in 10.7% patients. Cardiac death occurred in 2% of patients in the BVS group and in 2.7% of patients in the stent group. Target-vessel MI occurred in 5.5% of patients in the BVS group and in 3.2% of those in the stent group, and target-vessel revascularization occurred in 8.7% of patients in the BVS group and in 7.5% of patients in the stent group. Definite or probable device thrombosis occurred in 3.5% of patients in the BVS group, compared with 0.9% of patients in the stent group. The study was published on March 29, 2017, in the New England Journal of Medicine (NEJM).

“I certainly don’t think that it’s a workhorse stent in clinical practice. There are concerns about the risks of scaffold thrombosis and these have now been seen in several trials,” said lead author Joanna Wykrzykowska, MD, PhD, of AMC and ASZ. “So, if anybody uses it, it should be, perhaps, in fairly simple lesions with very careful lesion preparation and guidance to reduce the risks as much as possible. You also have to make sure that your patient can take long-term dual antiplatelet therapy.”

“Given the lack of an advantage with respect to clinical efficacy, the challenges in delivering the device (including longer procedural times), and the higher rate of device thrombosis with the bioresorbable scaffold, there is little justification for routine use of the everolimus-eluting bioresorbable scaffold over the everolimus-eluting metallic stent,” commented Debabrata Mukherjee, MD, of Texas Tech University Health Sciences Center (El Paso, USA), in an accompanying editorial.

For the study, the researchers compared the Absorb GT1 BVS scaffold, made of a biodegradable poly-L-lactic acid (PLLA) and a poly-D,L-lactide (PDLLA) polymer coating that controls the release of the anti-proliferative drug everolimus--a derivative of sirolimus--which functions as an inhibitor of mammalian target of rapamycin (mTOR). Everolimus is currently used as an immunosuppressant to prevent rejection of organ transplants and stents and as a treatment of renal cell cancer and other tumors.

Gold Member
12-Channel ECG
CM1200B
Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Acute Care Scale
PH-740

Print article

Channels

Surgical Techniques

view channel
Image: The multi-sensing device can be implanted into blood vessels to help physicians deliver timely treatment (Photo courtesy of IIT)

Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health

Researchers have embarked on a project to develop a multi-sensing device that can be implanted into blood vessels like peripheral veins or arteries to monitor a range of bodily parameters and overall health status.... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more