Bioluminescent Technology Verifies Endoscope Cleanliness

By HospiMedica International staff writers
Posted on 07 Aug 2017
Print article
Image: The EndoSwab is a single use absorbent sponge tip that identifies biological tissue (Photo courtesy of Hygiena).
Image: The EndoSwab is a single use absorbent sponge tip that identifies biological tissue (Photo courtesy of Hygiena).
A new testing system provides real-time verification of the cleanliness of endoscopes and other reusable medical instruments in just 15 seconds.

The Hygiena (Camarillo, CA, USA) EndoSwab is a single use, catheter-like device that features an absorbent sponge tip attached to a 2.4 meter long flexible wand, enabling sample collection from even hard-to-reach internal channels and components. Following swabbing sampling, the sponge tip is removed and assessed using proprietary adenosine triphosphate (ATP) test devices. Since ATP is a component of all bodily fluids, the test can verify the cleanliness--but not the sterility--of the endoscope. Once the initial cleaning steps have been confirmed, the instrument can then be disinfected, sterilized, and reused.

EndoSwab is compatible with the Hygiena UltraSnap and SuperSnap ATP surface test devices, two fully integrated, easy-to-use and environmentally-friendly systems capable of generating highly sensitive, accurate and reproducible results using a luminometer. Similarly, the Hygiena AquaSnap device can be used to verify water quality. The systems incorporate a software package for the recording of test data, which can then be used to generate graphs and reports that detect cleaning issues, identify personnel training needs, and monitor the overall cleanliness of an instrument inventory over time.

“Owing to the invasive nature of the procedures in which they are used, reusable medical devices are highly susceptible to contamination. As such, proper reprocessing between uses is necessary to avoid cross-contamination and infection outbreaks,” said Martin Easter, PhD, chief scientific officer of Hygiena. “EndoSwab allows for the easy collection of test samples on a daily basis and the rapid detection of contamination before patient exposure.”

ATP is a key factor of the bioluminescent reaction, a multistep process which mainly requires luciferine substrate, Oxygen (O2), Magnesium cation (Mg++) and ATP. The process relies on luciferine oxidation, with light intensity directly proportional to ATP content. The light emission is a consequence of a rapid loss of energy of the oxyluciferine molecule from an excited state to a stable one, a reaction that induces the emission of photons with an efficient quantum yield of about 90%.

Related Links:
Hygiena

Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
24.5-inch Full HD 2D OLED Medical Monitor
PVM-2551MD

Print article

Channels

Surgical Techniques

view channel
Image: ‘Wraparound’ implants represent a new approach to treating spinal cord injuries (Photo courtesy of 123RF)

Tiny Wraparound Electronic Implants to Revolutionize Treatment of Spinal Cord Injuries

The spinal cord functions as a vital conduit, transmitting nerve impulses to and from the brain, much like a highway. When the spinal cord is damaged, this flow of information is disrupted, leading to... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more