HospiMedica

Download Mobile App
Recent News AI Critical Care Surgical Techniques Patient Care Health IT Point of Care Business Focus

Post-Surgical X-Rays Predict Bunion Recurrence Risk

By HospiMedica International staff writers
Posted on 10 Aug 2017
Print article
Image: The clinical and radiographic appearance of a bunion (Photo courtesy of AAOS).
Image: The clinical and radiographic appearance of a bunion (Photo courtesy of AAOS).
Measuring the hallux valgus angle (HVA) on postoperative x-rays immediately following bunion surgery can reliably predict satisfactory correction and risk of recurrence.

Researchers at Yeungnam University (Daegu, South Korea) and Injie University Seoul Paik Hospital (Republic of Korea) conducted a study in 93 patients (for a total of 117 feet) who underwent proximal chevron osteotomy combined with a distal soft-tissue procedure in order to treat moderate to severe hallux valgus deformity. Changes in hallux valgus angle, inter-metatarsal angle, and sesamoid position over time were analyzed by comparing non-weight-bearing radiographs during each postoperative period.

The relative risks of recurrence, as indicated by preoperative and postoperative radiographic parameters were then determined. The results showed that hallux valgus angle and inter-metatarsal angle stabilized at six months after surgery in the nonrecurrence group. Hallux valgus recurrence was associated with an immediate postoperative hallux valgus angle higher than 8°, immediate postoperative sesamoid position of grade 4 or greater, a preoperative metatarsus adductus angle of 23° or higher, and a preoperative hallux valgus angle of higher than 40°. The study was published in the July 2017 issue of The Journal of Bone and Joint Surgery.

“Bunions were 28 times more likely to recur when the postoperative HVA was eight degrees or larger than when the HVA was less than eight degrees. The HVA continued to widen over time in patients with recurrent bunions, but stabilized at six months in those without recurrence,” concluded study authors Chul Hyun Park, MD, PhD, and Woo-Chun Lee, MD, PhD. “The recurrence of hallux valgus is one of the most important complications after surgery because it is closely related to patient satisfaction.”

A bunion is a painful bony bump that develops when the metatarsophalangeal (MTP) joints move out of alignment: the long metatarsal bone shifts toward the inside of the foot, and the phalanx bones of the big toe angle toward the second toe. The MTP joint gets larger and protrudes from the inside of the forefoot. The enlarged joint is often inflamed, red, and swollen. The word bunion, in fact, comes from the Greek word for turnip, hinting to its appearance.

Related Links:
Yeungnam University
Injie University Seoul Paik Hospital
Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Gold Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Compact C-Arm
Arcovis DRF-C S21

Print article

Channels

Critical Care

view channel
Image: The new risk assessment tool determines patient-specific risks of developing unfavorable outcomes with heart failure (Photo courtesy of 123RF)

Powerful AI Risk Assessment Tool Predicts Outcomes in Heart Failure Patients

Heart failure is a serious condition where the heart cannot pump sufficient blood to meet the body's needs, leading to symptoms like fatigue, weakness, and swelling in the legs and feet, and it can ultimately... Read more

Surgical Techniques

view channel
Image: The multi-sensing device can be implanted into blood vessels to help physicians deliver timely treatment (Photo courtesy of IIT)

Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health

Researchers have embarked on a project to develop a multi-sensing device that can be implanted into blood vessels like peripheral veins or arteries to monitor a range of bodily parameters and overall health status.... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more