Carbon Fiber Implants Beneficial for Oncological Patients
By HospiMedica International staff writers Posted on 15 Oct 2018 |
Image: An MRI of titanium pedicle screws (L) and CarboClear pedicle screws (R) (Photo courtesy of CarboFix).
A novel carbon fiber pedicle screw system restores the integrity of the spinal column in patients with advanced-stage cancer in whom life expectancy is too short to permit fusion.
The CarboFix Orthopedics (CarboFix; Herzliya, Israel) CarboClear Pedicle Screw System is intended to restore the integrity of the thoracic and lumbar spine--even in the absence of fusion--for a limited period in patients with advanced tumors. The implant system consists of pedicle screws, rods, intramedullary nails, plates, and locking elements in various dimensions, used to build a spinal construct; and of a set of instruments, intended to assist in the insertion and placement of the implants. The threaded portion of the pedicle screws is encased within a thin titanium shell.
The system elements are made of carbon fiber-reinforced polyetheretherketone (CFR-PEEK), consisting of continuous carbon fibers layered in a unidirectional, longitudinal orientation, as well as in a helical and diagonal orientation, which adhere together. The composite material makes the CarboFix implants radiolucent, which is beneficial during surgery and follow up on magnetic resonance imaging (MRI) and computerized tomography (CT) scans with minimal artifacts. The material also enables radiation therapy (RT) with no backscatters.
“These unique implants provide enhanced imaging follow-up and radiation treatment. These implants are a game changer for spinal oncology cases,” said Ron Szekely, director of VP sales and marketing at CarboFix. “This is another major breakthrough for CarboFix in its endeavor to bring the next revolution, using carbon fibers as the material of choice in orthopedic implants. We will continue to broaden our portfolio for the spine as we did with our full range trauma line.”
Carbon fiber implants provide unique advantages to the oncological patients, including enhanced RT planning capabilities, allowing dose optimization with minimal collateral tissue damage and enhanced follow up abilities due to artifacts-free MRI and CT. In addition, unparalleled fatigue strength supports the impaired healing process in such patients, as well as compatibility with particle radiation (proton and carbon ion) and other stereotactic radio-surgery modalities.
Related Links:
CarboFix Orthopedics
The CarboFix Orthopedics (CarboFix; Herzliya, Israel) CarboClear Pedicle Screw System is intended to restore the integrity of the thoracic and lumbar spine--even in the absence of fusion--for a limited period in patients with advanced tumors. The implant system consists of pedicle screws, rods, intramedullary nails, plates, and locking elements in various dimensions, used to build a spinal construct; and of a set of instruments, intended to assist in the insertion and placement of the implants. The threaded portion of the pedicle screws is encased within a thin titanium shell.
The system elements are made of carbon fiber-reinforced polyetheretherketone (CFR-PEEK), consisting of continuous carbon fibers layered in a unidirectional, longitudinal orientation, as well as in a helical and diagonal orientation, which adhere together. The composite material makes the CarboFix implants radiolucent, which is beneficial during surgery and follow up on magnetic resonance imaging (MRI) and computerized tomography (CT) scans with minimal artifacts. The material also enables radiation therapy (RT) with no backscatters.
“These unique implants provide enhanced imaging follow-up and radiation treatment. These implants are a game changer for spinal oncology cases,” said Ron Szekely, director of VP sales and marketing at CarboFix. “This is another major breakthrough for CarboFix in its endeavor to bring the next revolution, using carbon fibers as the material of choice in orthopedic implants. We will continue to broaden our portfolio for the spine as we did with our full range trauma line.”
Carbon fiber implants provide unique advantages to the oncological patients, including enhanced RT planning capabilities, allowing dose optimization with minimal collateral tissue damage and enhanced follow up abilities due to artifacts-free MRI and CT. In addition, unparalleled fatigue strength supports the impaired healing process in such patients, as well as compatibility with particle radiation (proton and carbon ion) and other stereotactic radio-surgery modalities.
Related Links:
CarboFix Orthopedics
Latest Surgical Techniques News
- Porous Gel Sponge Facilitates Rapid Hemostasis and Wound Healing
- Novel Rigid Endoscope System Enables Deep Tissue Imaging During Surgery
- Robotic Nerve ‘Cuffs’ Could Treat Various Neurological Conditions
- Flexible Microdisplay Visualizes Brain Activity in Real-Time To Guide Neurosurgeons
- Next-Gen Computer Assisted Vacuum Thrombectomy Technology Rapidly Removes Blood Clots
- Hydrogel-Based Miniaturized Electric Generators to Power Biomedical Devices
- Custom 3D-Printed Orthopedic Implants Transform Joint Replacement Surgery
- Wearable Technology Monitors and Analyzes Surgeons' Posture during Long Surgical Procedures
- Cutting-Edge Imaging Platform Detects Residual Breast Cancer Missed During Lumpectomy Surgery
- Computational Models Predict Heart Valve Leakage in Children
- Breakthrough Device Enables Clear and Real-Time Visual Guidance for Effective Cardiovascular Interventions
- World’s First Microscopic Probe to Revolutionize Early Cancer Diagnosis
- World’s Smallest Implantable Brain Stimulator Demonstrated in Human Patient
- Robotically Assisted Lung Transplants Could Soon Become a Reality
- AI to Provide Heart Transplant Surgeons with New Decision-Making Data
- New Surgical Tool Empowers Precision and Confidence in Operating Room