HospiMedica

Download Mobile App
Recent News AI Critical Care Surgical Techniques Patient Care Health IT Point of Care Business Focus

High Negative Pressure Limits Dispersion of Airborne Contaminants

By HospiMedica International staff writers
Posted on 24 Dec 2018
Print article
Image: An AIIR at Taipei City Hospital (Photo courtesy of Reuters/Corbis).
Image: An AIIR at Taipei City Hospital (Photo courtesy of Reuters/Corbis).
Maintaining a high negative pressure in hospital isolation rooms effectively limits the dispersion of airborne contaminants, according to a new study.

The study, part of a doctoral dissertation by a researcher at the University of Eastern Finland (UEF; Viestintä), was designed to determine the containment capability of hospital airborne infection isolation rooms (AIIRs) by measuring air change rates of the patient room and anteroom, pressure differences, contaminant removal, and contaminant transmission during door openings and human movement. The researchers used a tracer gas method to simulate the release of infectious agents from a patient.

The results showed that high air change rates do not ensure efficient removal of infectious agents in the breathing zone, but that local in AIIR airflow patterns are more important. Applying high mean negative pressure between the AIIR and the surroundings significantly limited particle transmission outside of the AIIR. But while an anteroom helped control particle transmission, the dilution was not effective enough, based on observed air change rates of the anterooms studied. The dissertation was presented at UEF on December 14, 2018, and published in the December 2018 issue of Annals of Work Exposures and Health.

“Generally, a healthcare worker does not stay in the anteroom more than 2–3 minutes, thus to achieve at least 90% contaminant removal, the minimum air change rate requirement of 40 liters per hour would be needed after entering the anteroom,” said dissertant Anna Kokkonen, MSc. “The findings of the present study can be utilized as a starting point when setting consistent negative pressure and ventilation design guidelines for contaminant containment.”

AIIRs are single-occupancy patient spaces designed to isolate airborne pathogens to a safe containment area. AIIRs are a specialized application of a hospital’s heating, ventilating, and air conditioning (HVAC) system, where the airflow supplied into the room is balanced with exhaust airflow to create negative differential pressure with respect to an adjacent space, usually the hallway or an anteroom, so that no airborne particulates escape into nursing staff or public areas. The exhaust air is expelled through dedicated ductwork to rooftop ventilation stacks, where atmospheric air provides sufficient dilution to make the resulting air safe.

Related Links:
University of Eastern Finland

Gold Member
Disposable Protective Suit For Medical Use
Disposable Protective Suit For Medical Use
Gold Member
12-Channel ECG
CM1200B
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Ventilator
TRventi-3D

Print article

Channels

Surgical Techniques

view channel
Image: The multi-sensing device can be implanted into blood vessels to help physicians deliver timely treatment (Photo courtesy of IIT)

Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health

Researchers have embarked on a project to develop a multi-sensing device that can be implanted into blood vessels like peripheral veins or arteries to monitor a range of bodily parameters and overall health status.... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more