We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

HospiMedica

Download Mobile App
Recent News AI Critical Care Surgical Techniques Patient Care Health IT Point of Care Business Focus

Stent Graft System Treats Thoracoabdominal Aortic Aneurysm

By HospiMedica International staff writers
Posted on 26 Oct 2019
Print article
Image: The Valiant TAAA Stent Graft System (Photo courtesy of Sanford Health).
Image: The Valiant TAAA Stent Graft System (Photo courtesy of Sanford Health).
A minimally invasive stent graft repairs thoracoabdominal aortic aneurysm (TAAA), a complex condition that causes the aorta to bulge into the abdomen.

The Medtronic (Dublin, Ireland) Valiant TAAA Stent Graft System is comprised of a thoracic bifurcation and visceral manifold graft, which work together to facilitate endovascular stenting of the visceral vessels--the renal, celiac, and superior mesenteric arteries--while maintaining blood flow to the visceral and infrarenal segments. The complexity of the design required the use of computational fluid dynamics simulations in order to create a geometrically correct model of each graft relative to the same aorta coordinates and positioning in the body trunk, as well as the arteries that feed the organs and extend into the legs.

The system is comprised of several sections that interlock into each other proximally. The topmost level includes a thoracic bifurcated graft and a visceral manifold that creates four visceral vessels. Each of the branch vessels is stented individually by bridging stents, which can thereafter accept further descending extensions. An infrarenal graft stent and iliac extensions are also available. Once flow has been secured to each of the involved branches, the open limb of the proximal compartmentalizing graft is extended distally, excluding the diseased segment of vessel.

“Taking the complex and making it simple has long been our goal for the treatment of TAAAs. Working with Medtronic could eventually place our solution in the hands of vascular surgeons around the world to help patients facing a life-threatening condition,” said vascular surgeon Patrick Kelly, MD, of Sanford Health (Sioux Falls, SD, USA), who developed the concept. “We hope that this will have a major impact on the treatment of one of the most challenging disease processes to face our specialty.”

TAAA results from continuous dilation of the descending thoracic aorta, which extends into the abdominal aorta. Degradation of structural proteins such as collagen and elastin, or a defect in their composition, leads to medial degeneration and weakening of the aortic wall. Subsequent dilatation results from hemodynamic forces on the arterial wall, as well as intrinsic changes in the composition of the arterial wall itself, which cause the diameter of the aorta to expand further and increase wall tension, thus creating a vicious cycle.

Gold Member
Real-Time Diagnostics Onscreen Viewer
GEMweb Live
Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Remote Controlled Digital Radiography and Fluoroscopy System
Eco Track-DRF - MARS 50/MARS50+/MARS 65/MARS 80

Print article

Channels

Critical Care

view channel
Image: The stretchable microneedle electrode arrays (Photo courtesy of Zhao Research Group)

Stretchable Microneedles to Help In Accurate Tracking of Abnormalities and Identifying Rapid Treatment

The field of personalized medicine is transforming rapidly, with advancements like wearable devices and home testing kits making it increasingly easy to monitor a wide range of health metrics, from heart... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more