Breakthrough Device Disrupts Implant Biofilm Buildup
By HospiMedica International staff writers Posted on 04 Nov 2019 |
Image: The BioPrax device applied to a metal disk (Photo courtesy of Douglas Levere / Garwood Medical Device).
A minimally invasive device helps eliminate biofilm infections on prosthetic knee implants during early intervention procedures.
The Garwood Medical Devices (Buffalo, NY, USA) BioPrax device is based on Cathodic Voltage Controlled Electrical Stimulation (CVCES), which helps to break down biofilm so that bacteria become visible to the immune system, and susceptible to pharmaceutical treatment. The low (1.8V) voltage electrical current is applied to the surface of the knee implant, converting it into a working electrode. Current is also passed through counter and reference electrodes, in such a way that that while the current through the counter electrode is varied, the electric potential of the working electrode is constant, relative to the electric potential of the reference electrode.
The resulting electrical fields create an environment that elicits antimicrobial activity against bacteria on the implant and in surrounding bone tissue. In animal studies conducted to date, BioPrax reduced the viability of clinical biofilms by up to 99.9% across multiple combinations of bacterial strains--including methicillin-resistant Staphylococcus aureus (MRSA)--and metal types, following application of constant cathodic voltage to commercially pure titanium for one hour. The technology will soon be expanded to help eliminate biofilm infections on other types of medically implanted metallic devices, including all artificial joints, bone screws and plates, and dental implants.
“Breakthrough Device designation by the FDA is recognition that BioPrax appears to be on the right path towards the treatment of periprosthetic joint infections in knee implant patients,” said Wayne Bacon, CEO of Garwood Medical Devices. “Our goal is to eliminate the need for follow-up surgeries. We think we can wipe out infection-causing bacteria before trouble starts.”
Biofilms protect bacterial communities via extracellular polymeric substances (EPS) that form a matrix (diffusion barrier) that limits antibiotic penetration and immobilizes them. The diffusive barrier also results in nutrient gradients that cause decreased growth and metabolic inactivity in parts of the biofilm, allowing persister cells to arise. The increased persister cell formation is particularly observed in Gram-negative bacterial biofilms, as their cell membranes are composed of lipopolysaccharides that further limit antibiotic penetration.
Related Links:
Garwood Medical Devices
The Garwood Medical Devices (Buffalo, NY, USA) BioPrax device is based on Cathodic Voltage Controlled Electrical Stimulation (CVCES), which helps to break down biofilm so that bacteria become visible to the immune system, and susceptible to pharmaceutical treatment. The low (1.8V) voltage electrical current is applied to the surface of the knee implant, converting it into a working electrode. Current is also passed through counter and reference electrodes, in such a way that that while the current through the counter electrode is varied, the electric potential of the working electrode is constant, relative to the electric potential of the reference electrode.
The resulting electrical fields create an environment that elicits antimicrobial activity against bacteria on the implant and in surrounding bone tissue. In animal studies conducted to date, BioPrax reduced the viability of clinical biofilms by up to 99.9% across multiple combinations of bacterial strains--including methicillin-resistant Staphylococcus aureus (MRSA)--and metal types, following application of constant cathodic voltage to commercially pure titanium for one hour. The technology will soon be expanded to help eliminate biofilm infections on other types of medically implanted metallic devices, including all artificial joints, bone screws and plates, and dental implants.
“Breakthrough Device designation by the FDA is recognition that BioPrax appears to be on the right path towards the treatment of periprosthetic joint infections in knee implant patients,” said Wayne Bacon, CEO of Garwood Medical Devices. “Our goal is to eliminate the need for follow-up surgeries. We think we can wipe out infection-causing bacteria before trouble starts.”
Biofilms protect bacterial communities via extracellular polymeric substances (EPS) that form a matrix (diffusion barrier) that limits antibiotic penetration and immobilizes them. The diffusive barrier also results in nutrient gradients that cause decreased growth and metabolic inactivity in parts of the biofilm, allowing persister cells to arise. The increased persister cell formation is particularly observed in Gram-negative bacterial biofilms, as their cell membranes are composed of lipopolysaccharides that further limit antibiotic penetration.
Related Links:
Garwood Medical Devices
Latest Surgical Techniques News
- Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health
- Tiny Robots Made Out Of Carbon Could Conduct Colonoscopy, Pelvic Exam or Blood Test
- Miniaturized Ultrasonic Scalpel Enables Faster and Safer Robotic-Assisted Surgery
- AI Assisted Reading Tool for Small Bowel Video Capsule Endoscopy Detects More Lesions
- First-Ever Contact Force Pulsed Field Ablation System to Transform Treatment of Ventricular Arrhythmias
- Caterpillar Robot with Built-In Steering System Crawls Easily Through Loops and Bends
- Tiny Wraparound Electronic Implants to Revolutionize Treatment of Spinal Cord Injuries
- Small, Implantable Cardiac Pump to Help Children Awaiting Heart Transplant
- Gastrointestinal Imaging Capsule a Game-Changer in Esophagus Surveillance and Treatment
- World’s Smallest Laser Probe for Brain Procedures Facilitates Ablation of Full Range of Targets
- Artificial Intelligence Broadens Diagnostic Abilities of Conventional Coronary Angiography
- AI-Powered Surgical Visualization Tool Supports Surgeons' Visual Recognition in Real Time
- Cutting-Edge Robotic Bronchial Endoscopic System Provides Prompt Intervention during Emergencies
- Handheld Device for Fluorescence-Guided Surgery a Game Changer for Removal of High-Grade Glioma Brain Tumors
- Porous Gel Sponge Facilitates Rapid Hemostasis and Wound Healing
- Novel Rigid Endoscope System Enables Deep Tissue Imaging During Surgery