Gastrointestinal Bypass Device Offers an Alternative to Diverting Stoma
By HospiMedica International staff writers Posted on 20 Jan 2020 |
Image: An intraluminal bypass device reduces diverting stoma complications (Photo courtesy of Colospan)
A novel temporary intraluminal bypass device reduces diverting stoma rates in patients undergoing gastrointestinal resection procedures.
The Colospan (Kfar Saba, Israel) CG-100 is designed to reduce the rate of diverting stoma and related complications by diverting fecal material from contacting with the anastomotic site during the initial critical healing period. The device itself is comprised of a tubular silicone sheath that is introduced into the lumen of the intestinal tract through the anus, using a designated delivery system. The sheath is positioned proximal of the anastomosis. At the distal part of the sheath there are three inflatable balloons and an extra-luminal ring which encircles the colon.
The diameter of the balloon is slightly larger than that of the ring, preventing the sheath from moving downstream beyond the ring location, while still allowing it to move freely inside the colon, preventing damage to the colon wall. After ten days, when the risk for anastomotic leakage is reduced, the sheath is removed under x-ray guidance without any additional surgical intervention, in a procedure that requires only a few minutes. The CG-100 has received the European Community (EC) mark of approval and has been granted an U.S Food and Drug Administration (FDA) investigational device exemption (IDE).
“Colospan will launch a prospective, randomized pivotal study which is a leap forward towards bringing our novel device closer to the market,” said Boaz Assaf, CEO of Colospan. “The pivotal study will allow us to assess the potential of our device to improve patients' lives, significantly reduce healthcare costs, and as a result empower physicians to deliver an improved standard of care.”
The major concern of colorectal surgeons is anastomotic leakage of colon content into the abdominal cavity, which often necessitates a diverting stoma to prevent anastomotic leakage during the healing period. But diverting stoma is known to cause significant complications during its presence, which can last up to six months, and as a result of the second procedure required for stoma closure. Given the risks associated with stomas, a temporary diversion solution can provide surgeons as an alternative, short solution.
Related Links:
Colospan
The Colospan (Kfar Saba, Israel) CG-100 is designed to reduce the rate of diverting stoma and related complications by diverting fecal material from contacting with the anastomotic site during the initial critical healing period. The device itself is comprised of a tubular silicone sheath that is introduced into the lumen of the intestinal tract through the anus, using a designated delivery system. The sheath is positioned proximal of the anastomosis. At the distal part of the sheath there are three inflatable balloons and an extra-luminal ring which encircles the colon.
The diameter of the balloon is slightly larger than that of the ring, preventing the sheath from moving downstream beyond the ring location, while still allowing it to move freely inside the colon, preventing damage to the colon wall. After ten days, when the risk for anastomotic leakage is reduced, the sheath is removed under x-ray guidance without any additional surgical intervention, in a procedure that requires only a few minutes. The CG-100 has received the European Community (EC) mark of approval and has been granted an U.S Food and Drug Administration (FDA) investigational device exemption (IDE).
“Colospan will launch a prospective, randomized pivotal study which is a leap forward towards bringing our novel device closer to the market,” said Boaz Assaf, CEO of Colospan. “The pivotal study will allow us to assess the potential of our device to improve patients' lives, significantly reduce healthcare costs, and as a result empower physicians to deliver an improved standard of care.”
The major concern of colorectal surgeons is anastomotic leakage of colon content into the abdominal cavity, which often necessitates a diverting stoma to prevent anastomotic leakage during the healing period. But diverting stoma is known to cause significant complications during its presence, which can last up to six months, and as a result of the second procedure required for stoma closure. Given the risks associated with stomas, a temporary diversion solution can provide surgeons as an alternative, short solution.
Related Links:
Colospan
Latest Surgical Techniques News
- Miniaturized Ultrasonic Scalpel Enables Faster and Safer Robotic-Assisted Surgery
- AI Assisted Reading Tool for Small Bowel Video Capsule Endoscopy Detects More Lesions
- First-Ever Contact Force Pulsed Field Ablation System to Transform Treatment of Ventricular Arrhythmias
- Caterpillar Robot with Built-In Steering System Crawls Easily Through Loops and Bends
- Tiny Wraparound Electronic Implants to Revolutionize Treatment of Spinal Cord Injuries
- Small, Implantable Cardiac Pump to Help Children Awaiting Heart Transplant
- Gastrointestinal Imaging Capsule a Game-Changer in Esophagus Surveillance and Treatment
- World’s Smallest Laser Probe for Brain Procedures Facilitates Ablation of Full Range of Targets
- Artificial Intelligence Broadens Diagnostic Abilities of Conventional Coronary Angiography
- AI-Powered Surgical Visualization Tool Supports Surgeons' Visual Recognition in Real Time
- Cutting-Edge Robotic Bronchial Endoscopic System Provides Prompt Intervention during Emergencies
- Handheld Device for Fluorescence-Guided Surgery a Game Changer for Removal of High-Grade Glioma Brain Tumors
- Porous Gel Sponge Facilitates Rapid Hemostasis and Wound Healing
- Novel Rigid Endoscope System Enables Deep Tissue Imaging During Surgery
- Robotic Nerve ‘Cuffs’ Could Treat Various Neurological Conditions
- Flexible Microdisplay Visualizes Brain Activity in Real-Time To Guide Neurosurgeons