Augmented Reality Surgical Navigation Minimizes Radiation Exposure
By HospiMedica International staff writers Posted on 24 Feb 2020 |
Image: A hybrid OR equipped with the Allura Clarity Flexmove robotic C-arm (Photo courtesy of Maquet)
A new study suggests that using an augmented reality surgical navigation (ARSN) system in a hybrid operating room (OR) environment can minimize occupational radiation exposure.
Researchers at Karolinska University Hospital (Stockholm, Sweden), the Karolinska Institutet (KI; Solna, Sweden), and Philips Healthcare (Philips; Best, the Netherlands) conducted a study involving 20 patients scheduled for spine surgery with pedicle screw placement. The surgical procedures were performed in a hybrid OR using the ceiling-mounted Philips Allura Clarity Flexmove robotic C-arm, with the aid of an integrated ARSN system.
Two dimensional (2D) fluoroscopy imaging was used for spinal level identification and an intraoperative cone beam computerized tomography (CBCT) image was acquired for navigation planning and screw placement. Another CBCT was performed to confirm correct screw placement prior to wound closure, instead of a postoperative CT. Staff radiation exposure was measured using real-time active personnel dosimeters, and was further compared with measurements using a reference dosimeter attached to the C-arm. Patient radiation exposure characteristics were extracted from radiation dose structured reports (RDSR) in order to estimate effective doses (ED).
The results revealed that average staff-to-reference dose ratio per procedure was 0.05%, and decreased to less than 0.01% after a few procedures had been performed using the ARSN. Average patient ED was mainly correlated with the number of vertebrae treated and the number of CBCTs performed. The low-dose protocol used for the final 10 procedures yielded a 32% ED reduction per spinal level treated. The researchers added that using real-time active personnel dosimeters contributed to fast optimization and adoption of protective measures throughout the study. The study was published on January 1, 2020, in Spine.
“Patient radiation dose was reduced by using a low-dose protocol with fewer x-ray pulses per second and a larger field of view, thereby improving the ratio between number of imaged spinal levels and total dose,” concluded lead author Erik Edström, MD, PhD, of KI, and colleagues. “This study demonstrates that relatively low patient radiation doses are possible with an ARSN system for spine surgery in a hybrid OR.”
The use of 3D imaging obtained by a C-arm or a computed tomography (CT) system for intraoperative pedicle screw planning, placement, assessment, and revision has increased substantially. When used in conjunction with an ASRD system, the risk of screw misplacement is significantly reduced. And although the technique may increase total radiation exposure (compared to fluoroscopy), occupational exposure can be minimized, as ARSN is radiation free, and staff can be positioned behind protective shielding during imaging.
Related Links:
Karolinska University Hospital
Karolinska Institutet
Philips Healthcare
Researchers at Karolinska University Hospital (Stockholm, Sweden), the Karolinska Institutet (KI; Solna, Sweden), and Philips Healthcare (Philips; Best, the Netherlands) conducted a study involving 20 patients scheduled for spine surgery with pedicle screw placement. The surgical procedures were performed in a hybrid OR using the ceiling-mounted Philips Allura Clarity Flexmove robotic C-arm, with the aid of an integrated ARSN system.
Two dimensional (2D) fluoroscopy imaging was used for spinal level identification and an intraoperative cone beam computerized tomography (CBCT) image was acquired for navigation planning and screw placement. Another CBCT was performed to confirm correct screw placement prior to wound closure, instead of a postoperative CT. Staff radiation exposure was measured using real-time active personnel dosimeters, and was further compared with measurements using a reference dosimeter attached to the C-arm. Patient radiation exposure characteristics were extracted from radiation dose structured reports (RDSR) in order to estimate effective doses (ED).
The results revealed that average staff-to-reference dose ratio per procedure was 0.05%, and decreased to less than 0.01% after a few procedures had been performed using the ARSN. Average patient ED was mainly correlated with the number of vertebrae treated and the number of CBCTs performed. The low-dose protocol used for the final 10 procedures yielded a 32% ED reduction per spinal level treated. The researchers added that using real-time active personnel dosimeters contributed to fast optimization and adoption of protective measures throughout the study. The study was published on January 1, 2020, in Spine.
“Patient radiation dose was reduced by using a low-dose protocol with fewer x-ray pulses per second and a larger field of view, thereby improving the ratio between number of imaged spinal levels and total dose,” concluded lead author Erik Edström, MD, PhD, of KI, and colleagues. “This study demonstrates that relatively low patient radiation doses are possible with an ARSN system for spine surgery in a hybrid OR.”
The use of 3D imaging obtained by a C-arm or a computed tomography (CT) system for intraoperative pedicle screw planning, placement, assessment, and revision has increased substantially. When used in conjunction with an ASRD system, the risk of screw misplacement is significantly reduced. And although the technique may increase total radiation exposure (compared to fluoroscopy), occupational exposure can be minimized, as ARSN is radiation free, and staff can be positioned behind protective shielding during imaging.
Related Links:
Karolinska University Hospital
Karolinska Institutet
Philips Healthcare
Latest Surgical Techniques News
- AI Assisted Reading Tool for Small Bowel Video Capsule Endoscopy Detects More Lesions
- First-Ever Contact Force Pulsed Field Ablation System to Transform Treatment of Ventricular Arrhythmias
- Caterpillar Robot with Built-In Steering System Crawls Easily Through Loops and Bends
- Tiny Wraparound Electronic Implants to Revolutionize Treatment of Spinal Cord Injuries
- Small, Implantable Cardiac Pump to Help Children Awaiting Heart Transplant
- Gastrointestinal Imaging Capsule a Game-Changer in Esophagus Surveillance and Treatment
- World’s Smallest Laser Probe for Brain Procedures Facilitates Ablation of Full Range of Targets
- Artificial Intelligence Broadens Diagnostic Abilities of Conventional Coronary Angiography
- AI-Powered Surgical Visualization Tool Supports Surgeons' Visual Recognition in Real Time
- Cutting-Edge Robotic Bronchial Endoscopic System Provides Prompt Intervention during Emergencies
- Handheld Device for Fluorescence-Guided Surgery a Game Changer for Removal of High-Grade Glioma Brain Tumors
- Porous Gel Sponge Facilitates Rapid Hemostasis and Wound Healing
- Novel Rigid Endoscope System Enables Deep Tissue Imaging During Surgery
- Robotic Nerve ‘Cuffs’ Could Treat Various Neurological Conditions
- Flexible Microdisplay Visualizes Brain Activity in Real-Time To Guide Neurosurgeons
- Next-Gen Computer Assisted Vacuum Thrombectomy Technology Rapidly Removes Blood Clots