High-Risk Hospital Surfaces Exacerbate Coronavirus Spread

By HospiMedica International staff writers
Posted on 23 Sep 2020
Print article
Hospital bedrails, door handles, and electrocardiogram (ECG) monitors are hotspots for SARS-CoV-2 contamination, claims a new study.

Researchers at the Sichuan Center of Disease Control (CDC; Chengdu, China), Fudan University (Shanghai, China), and other institutions collected samples from 31 surfaces in different hospital wards before daily cleaning and disinfection routines were implemented. For each positive SARS-CoV-2 case, seven surfaces were designated, including bedrails, the fingertip of ECG monitors, and bathroom door handles. The method used for SARS-CoV-2 identification was loop-mediated isothermal amplification (LAMP), which uses the N gene for detection.

In all, the researchers obtained 49 positive results from 14 positive cases, with two to six contamination sites identified per case. More than 70% of surfaces were contaminated by the virus from confirmed COVID-19 cases, which indicates a strong chance of cross-infection by surfaces in isolation wards. Over 70% of positive cases showed contamination of the ECG fingertip, which showed a higher viral RNA as well; the second highest risk was with the bedrail, with 10 positive samples. The study was published in the September 2020 issue of Science of The Total Environment.

“Virus monitoring should be added as a routine procedure in ward management. The door handles and fingertips of ECG monitors should be sampled daily for contamination analysis,” concluded senior author Guodong Sui, PhD, of Fudan University, and colleagues. “If the sample from a door handle obtains a positive result, a more precise and thorough cleaning should be performed. As surface contamination may cause nosocomial viral infection, general cleaning is mandatory in wards.”

SARS-CoV-2 is an enveloped virus; as such, it is very susceptible to most cleaning agents, which destroys the envelope and deactivates the virus. When left untreated, SARS-CoV-2 remains viable for up to 72 hours on plastic and steel surfaces, and for up to eight hours on copper and cardboard surfaces.

Related Links:
Sichuan Center of Disease Control
Fudan University


Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Gold Member
12-Channel ECG
CM1200B
Silver Member
Compact 14-Day Uninterrupted Holter ECG
NR-314P
New
Ventilator
TRventi-3D

Print article

Channels

Surgical Techniques

view channel
Image: The multi-sensing device can be implanted into blood vessels to help physicians deliver timely treatment (Photo courtesy of IIT)

Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health

Researchers have embarked on a project to develop a multi-sensing device that can be implanted into blood vessels like peripheral veins or arteries to monitor a range of bodily parameters and overall health status.... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Health IT

view channel
Image: First ever institution-specific model provides significant performance advantage over current population-derived models (Photo courtesy of Mount Sinai)

Machine Learning Model Improves Mortality Risk Prediction for Cardiac Surgery Patients

Machine learning algorithms have been deployed to create predictive models in various medical fields, with some demonstrating improved outcomes compared to their standard-of-care counterparts.... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more