New Surgical Tool Holds Orthopedic Procedures in Check
By HospiMedica International staff writers Posted on 09 Mar 2016 |
Image: The BendGuide opto-electronic drilling system (Photo courtesy of HUJI – Hebrew University Jerusalem, Israel).
A novel drill guide will enable surgeons to perform highly accurate hip fracture and spinal fusion procedures with minimal side effects.
Developed by researchers of the BioDesign team at the Hebrew University (HUJI; Jerusalem, Israel) and Hadassah Medical Center (Jerusalem, Israel), the BendGuide opto-electronic drilling system provides real-time indication of deflection or bending of the guide-wire during orthopedic surgery. This allows surgeons to adjust drilling trajectories to the correct angulations before any damage occurs, and ensure that fixation screws are placed properly.
The system, which uses a fiber-optic guidewire with a reflecting laser beam, enables detection of small deflections in wire trajectory. At a fully-aligned state, the beam power hits the center of the detector array; when deflected, mirror misalignment causes the power to spread differentially across the fiber bundle, indicating a trajectory shift. The fiber bundle also eliminates guide-wire bending or breakage, while enhancing safety and significantly reducing operation times.
“This is an elegant technological solution to a complex problem,” said Prof. Yaakov Nahmias, PhD, director of the HUJI BioDesign center for bioengineering. “The group model and proof-of-concept experiments showed they could detect even miniscule changes in guide-wire trajectory.”
Hip fracture fixation is performed on 258,000 patients a year in the United States alone, while spinal fusion accounts for a further 350,000. As the population ages and obesity increases, the number of these surgical procedures is expected to grow. Complications in guide-wire positioning during fusion procedures can lead to revision surgeries and increase hospitalization time and cost.
Related Links:
The Hebrew University, Jerusalem
Hadassah Medical Center
Developed by researchers of the BioDesign team at the Hebrew University (HUJI; Jerusalem, Israel) and Hadassah Medical Center (Jerusalem, Israel), the BendGuide opto-electronic drilling system provides real-time indication of deflection or bending of the guide-wire during orthopedic surgery. This allows surgeons to adjust drilling trajectories to the correct angulations before any damage occurs, and ensure that fixation screws are placed properly.
The system, which uses a fiber-optic guidewire with a reflecting laser beam, enables detection of small deflections in wire trajectory. At a fully-aligned state, the beam power hits the center of the detector array; when deflected, mirror misalignment causes the power to spread differentially across the fiber bundle, indicating a trajectory shift. The fiber bundle also eliminates guide-wire bending or breakage, while enhancing safety and significantly reducing operation times.
“This is an elegant technological solution to a complex problem,” said Prof. Yaakov Nahmias, PhD, director of the HUJI BioDesign center for bioengineering. “The group model and proof-of-concept experiments showed they could detect even miniscule changes in guide-wire trajectory.”
Hip fracture fixation is performed on 258,000 patients a year in the United States alone, while spinal fusion accounts for a further 350,000. As the population ages and obesity increases, the number of these surgical procedures is expected to grow. Complications in guide-wire positioning during fusion procedures can lead to revision surgeries and increase hospitalization time and cost.
Related Links:
The Hebrew University, Jerusalem
Hadassah Medical Center
Latest Surgical Techniques News
- Flexible Microdisplay Visualizes Brain Activity in Real-Time To Guide Neurosurgeons
- Next-Gen Computer Assisted Vacuum Thrombectomy Technology Rapidly Removes Blood Clots
- Hydrogel-Based Miniaturized Electric Generators to Power Biomedical Devices
- Custom 3D-Printed Orthopedic Implants Transform Joint Replacement Surgery
- Wearable Technology Monitors and Analyzes Surgeons' Posture during Long Surgical Procedures
- Cutting-Edge Imaging Platform Detects Residual Breast Cancer Missed During Lumpectomy Surgery
- Computational Models Predict Heart Valve Leakage in Children
- Breakthrough Device Enables Clear and Real-Time Visual Guidance for Effective Cardiovascular Interventions
- World’s First Microscopic Probe to Revolutionize Early Cancer Diagnosis
- World’s Smallest Implantable Brain Stimulator Demonstrated in Human Patient
- Robotically Assisted Lung Transplants Could Soon Become a Reality
- AI to Provide Heart Transplant Surgeons with New Decision-Making Data
- New Surgical Tool Empowers Precision and Confidence in Operating Room
- Future Muscle-Powered Surgical Robots Could Perform Minimally Invasive Procedures inside Body
- Non-Invasive Technique Combines Cardiac CT with AI-Powered Blood Flow for Heart Bypass Surgery
- First-Of-Its-Kind Device Repairs Leaky Tricuspid Heart Valve