Adjustable Transobturator Effectively Treats Male Incontinence
By Daniel Beris Posted on 07 Dec 2016 |
Image: The ATOMS device with the scrotal port (Photo courtesy of AMI).
An innovative implantable system with no mechanical parts provides an effective treatment for mild to severe male stress urinary incontinence (SUI).
The adjustable transobturator male system (ATOMS) is a long-term, adjustable implant designed to treat male SUI, generally following invasive treatment of the prostate gland. The implant is based on a suburethral substitute sphincter cushion that provides a gentle, evenly distributed pressure on the bulbospongiosus muscle in order to reduce the risk of urethral erosion. There is no specific point of maximum compression on the urethra, and patients can urinate freely, without having to activate a mechanical component.
The cushion is located in the middle of a mesh fixation tape, with integrated mesh arms that are drawn back around to the middle of the implant and over the inferior pubic ramus to secure the system in place, providing 4-point-fixation that eliminates the need for fasteners or screws. The macroporous mesh integrates into the bone, leading to an extra firm hold. Tissue ingrowth and revascularization of the surrounding tissue reduce the risk of an infection spreading in the pelvis operatively or post-operatively.
Following placement, the substitute sphincter cushion is filled via a scrotal port-catheter connection; the patient-specific adjustments require no further surgical intervention, and can be made at any time to counteract either continuing incontinence or urinary retention. From then on, the ATOMS cushion exerts gentle compression pressure on the bulbospongiosus muscle, and thus indirectly of the urethra, increasing urethral resistance. Involuntary loss of urine is thus reduced or ideally avoided. The ATOMS device is a product of the Agency for Medical Innovations (AMI; Feldkirch, Austria).
“The ATOMS device is safe and shows high treatment efficacy and patient satisfaction in the largest cohort study to date,” said Alexander Friedl, MD, of Hospital Göttlicher Heiland (Vienna, Austria), who led a recent international study of the device. “The latest generation, with its pre-attached silicone-covered scrotal port, is superior to its predecessors. Significantly better results were achieved with primary implantation and in those without a history of radiotherapy.”
In men, SUI usually results from a procedure to remove an enlarged prostate that causes difficulty in urinating. The resulting surgical damage to the urinary sphincter leads to incontinence, or creates functional problems. When the strength of the sphincter muscle is compromised, urine may leak through the urethra. Under pressure to the bladder, such as with a golf swing or a sneeze, leakage may be slight. However, depending on the severity of damage, the impaired sphincter could allow a steady stream of urine.
Related Links:
Agency for Medical Innovations
Hospital Göttlicher Heiland
The adjustable transobturator male system (ATOMS) is a long-term, adjustable implant designed to treat male SUI, generally following invasive treatment of the prostate gland. The implant is based on a suburethral substitute sphincter cushion that provides a gentle, evenly distributed pressure on the bulbospongiosus muscle in order to reduce the risk of urethral erosion. There is no specific point of maximum compression on the urethra, and patients can urinate freely, without having to activate a mechanical component.
The cushion is located in the middle of a mesh fixation tape, with integrated mesh arms that are drawn back around to the middle of the implant and over the inferior pubic ramus to secure the system in place, providing 4-point-fixation that eliminates the need for fasteners or screws. The macroporous mesh integrates into the bone, leading to an extra firm hold. Tissue ingrowth and revascularization of the surrounding tissue reduce the risk of an infection spreading in the pelvis operatively or post-operatively.
Following placement, the substitute sphincter cushion is filled via a scrotal port-catheter connection; the patient-specific adjustments require no further surgical intervention, and can be made at any time to counteract either continuing incontinence or urinary retention. From then on, the ATOMS cushion exerts gentle compression pressure on the bulbospongiosus muscle, and thus indirectly of the urethra, increasing urethral resistance. Involuntary loss of urine is thus reduced or ideally avoided. The ATOMS device is a product of the Agency for Medical Innovations (AMI; Feldkirch, Austria).
“The ATOMS device is safe and shows high treatment efficacy and patient satisfaction in the largest cohort study to date,” said Alexander Friedl, MD, of Hospital Göttlicher Heiland (Vienna, Austria), who led a recent international study of the device. “The latest generation, with its pre-attached silicone-covered scrotal port, is superior to its predecessors. Significantly better results were achieved with primary implantation and in those without a history of radiotherapy.”
In men, SUI usually results from a procedure to remove an enlarged prostate that causes difficulty in urinating. The resulting surgical damage to the urinary sphincter leads to incontinence, or creates functional problems. When the strength of the sphincter muscle is compromised, urine may leak through the urethra. Under pressure to the bladder, such as with a golf swing or a sneeze, leakage may be slight. However, depending on the severity of damage, the impaired sphincter could allow a steady stream of urine.
Related Links:
Agency for Medical Innovations
Hospital Göttlicher Heiland
Latest Surgical Techniques News
- Flexible Microdisplay Visualizes Brain Activity in Real-Time To Guide Neurosurgeons
- Next-Gen Computer Assisted Vacuum Thrombectomy Technology Rapidly Removes Blood Clots
- Hydrogel-Based Miniaturized Electric Generators to Power Biomedical Devices
- Custom 3D-Printed Orthopedic Implants Transform Joint Replacement Surgery
- Wearable Technology Monitors and Analyzes Surgeons' Posture during Long Surgical Procedures
- Cutting-Edge Imaging Platform Detects Residual Breast Cancer Missed During Lumpectomy Surgery
- Computational Models Predict Heart Valve Leakage in Children
- Breakthrough Device Enables Clear and Real-Time Visual Guidance for Effective Cardiovascular Interventions
- World’s First Microscopic Probe to Revolutionize Early Cancer Diagnosis
- World’s Smallest Implantable Brain Stimulator Demonstrated in Human Patient
- Robotically Assisted Lung Transplants Could Soon Become a Reality
- AI to Provide Heart Transplant Surgeons with New Decision-Making Data
- New Surgical Tool Empowers Precision and Confidence in Operating Room
- Future Muscle-Powered Surgical Robots Could Perform Minimally Invasive Procedures inside Body
- Non-Invasive Technique Combines Cardiac CT with AI-Powered Blood Flow for Heart Bypass Surgery
- First-Of-Its-Kind Device Repairs Leaky Tricuspid Heart Valve