Custom-Designed Prosthetic Foot Mimics Natural Walking

By HospiMedica International staff writers
Posted on 11 Jul 2018
Print article
Image: Prototype prosthetic feet on Indian volunteers (Photo courtesy of MIT).
Image: Prototype prosthetic feet on Indian volunteers (Photo courtesy of MIT).
A low-cost passive prosthetic foot can be individually tailored so that the user’s walk is similar to that of an able-bodied gait.

Developed by researchers at the Massachusetts Institute of Technology (MIT, Cambridge, MA, USA), the prosthetic foot is based on a mathematical model that describes stiffness, motion, and shape of the foot, and also relates to how the lower leg moves while the foot is in contact with the ground. The researchers first consulted an existing dataset of measurements of steps taken by an able-bodied walker with a given body size and weight. Ground reaction forces and the changing center of pressure experienced by a walker’s foot as it rocked from heel to toe were measured, predicting how a user’s lower leg would translate through a single step.

Using the mathematical model, the researchers then tuned the stiffness and geometry of the simulated prosthetic foot to produce a lower-leg trajectory that was close to that of the able-bodied swing. To develop the prosthetic foot itself, they decided not to replicate an anatomic human foot, but rather take a different approach, one based on their realization that amputees who have lost a limb below the knee cannot feel what a prosthetic foot does, as it is not connected to the nervous system, and therefore, there is no interaction.

The resulting foot shape looks similar to the side-view of a toboggan ski, and can be customized using just a few select variables such as body weight and size, which are modified in the genetic algorithm. The prosthesis’ plantar section is made from machined nylon, a material chosen for its energy-storage capability. To test the prototype model, the researchers produced several feet for volunteers in India. They estimate that the foot, if manufactured on a wide scale, could cost an order of magnitude less than existing products. The study was published in the March 2018 issue of the Journal of Mechanisms and Robotics.

“What’s cool is, this behaves nothing like an able-bodied foot, there’s no ankle or metatarsal joint, it’s just one big structure, and all we care about is how the lower leg is moving through space. Most of the testing was done indoors, but one guy ran outside, he liked it so much,” said lead author mechanical engineer Amos Winter, of MIT. “A common passive foot in the U.S. market will cost USD 1,000 to USD 10,000, made out of carbon fiber. Imagine you go to your prosthetist, they take a few measurements, they send them back to us, and we send back to you a custom-designed nylon foot for a few hundred bucks.”

The researchers have partnered with Vibram, which manufactures rubber outsoles for flexible hiking boots and running shoes that look like feet. The company is designing a life-like covering for the team’s prosthesis that will also give the foot some traction over muddy or slippery surfaces. The researchers plan to test the prosthetics and coverings on volunteers in India in Spring 2018.

Related Links:
Massachusetts Institute of Technology

Gold Member
SARS‑CoV‑2/Flu A/Flu B/RSV Sample-To-Answer Test
SARS‑CoV‑2/Flu A/Flu B/RSV Cartridge (CE-IVD)
Gold Member
Disposable Protective Suit For Medical Use
Disposable Protective Suit For Medical Use
Silver Member
Wireless Mobile ECG Recorder
NR-1207-3/NR-1207-E
New
Illuminated Retractor System
HandLite

Print article

Channels

Critical Care

view channel
Image: The new risk assessment tool determines patient-specific risks of developing unfavorable outcomes with heart failure (Photo courtesy of 123RF)

Powerful AI Risk Assessment Tool Predicts Outcomes in Heart Failure Patients

Heart failure is a serious condition where the heart cannot pump sufficient blood to meet the body's needs, leading to symptoms like fatigue, weakness, and swelling in the legs and feet, and it can ultimately... Read more

Surgical Techniques

view channel
Image: The multi-sensing device can be implanted into blood vessels to help physicians deliver timely treatment (Photo courtesy of IIT)

Miniaturized Implantable Multi-Sensors Device to Monitor Vessels Health

Researchers have embarked on a project to develop a multi-sensing device that can be implanted into blood vessels like peripheral veins or arteries to monitor a range of bodily parameters and overall health status.... Read more

Patient Care

view channel
Image: The portable, handheld BeamClean technology inactivates pathogens on commonly touched surfaces in seconds (Photo courtesy of Freestyle Partners)

First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds

Reducing healthcare-acquired infections (HAIs) remains a pressing issue within global healthcare systems. In the United States alone, 1.7 million patients contract HAIs annually, leading to approximately... Read more

Point of Care

view channel
Image: The Quantra Hemostasis System has received US FDA special 510(k) clearance for use with its Quantra QStat Cartridge (Photo courtesy of HemoSonics)

Critical Bleeding Management System to Help Hospitals Further Standardize Viscoelastic Testing

Surgical procedures are often accompanied by significant blood loss and the subsequent high likelihood of the need for allogeneic blood transfusions. These transfusions, while critical, are linked to various... Read more