Reusable Mattress Warmer Treats Neonatal Hypothermia
By HospiMedica International staff writers Posted on 18 May 2021 |
Image: The 12 phase change material “candles” that maintain Dream Warmer temperatures (Photo courtesy of PureTemp)
A low-cost, non-electric, reusable infant mattress based on the concept of a heating pad can help prevent and treat hypothermia in newborns, according to a new study.
The Dream Warmer, developed by researchers at Partners In Health/Inshuti Mu Buzima (PIH/IMB; Kigali, Rwanda), Boston Children’s Hospital (BCH; MA, USA), and other institutions, is based on a mattress containing 12 phase change material “candles” designed by PureTemp (Minneapolis, MN, USA) that melt to skin temperature and remain so for up to six hours. Once cooled down, the mattress can be cleaned and reused multiple times. It was specifically designed to complement skin-to-skin care (SSC) kangaroo mother care (KMC), either when it provides insufficient heat or if the mother needs to take a break.
To test the mattress, the researchers conducted a cluster-randomized stepped-wedge trial to assess its effect on euthermia and mortality, compared to standard of care in rural Rwandan hospitals. Ten district hospitals enrolled 464 unique infants who used the warmer 892 times. The results showed euthermia rates rose from 51% to 67%; among the encounters in which the warmer was used, only 11% remained hypothermic. Mortality rate among those who used the warmer (0.9%) were also significantly lower than among those who did not (2.8%). The study was published on April 16, 2021, in eClinicalMedicine.
“Infant hypothermia is a silent killer, but it's a modifiable risk factor, and this study shows that reducing it can have a large impact on survival and also likely on the long-term neurodevelopment of these babies,” said senior author Anne Hansen, MD, MPH, of BCH. “This is a good option for treatment in setting where incubators are not the right solution, whether it is because they are too expensive, require electricity, or require extensive training to correctly use and maintain.”
KMC was introduced in 1978 by Edgar Rey Sanabria, MD, in Bogotá (Colombia) as an alternative to incubators for low birth weight infants. KMC has four components: early, continuous, and prolonged SSC between the newborn and mother; exclusive breastfeeding; early discharge from the health facility; and close follow-up at home. It is thought to improve neonatal outcomes by maintaining infant temperature through SSC and by providing the benefits of breastfeeding, which are beneficial for all newborns, but may be especially advantageous for preterm infants.
Related Links:
Partners In Health/Inshuti Mu Buzima
Boston Children’s Hospital
PureTemp
The Dream Warmer, developed by researchers at Partners In Health/Inshuti Mu Buzima (PIH/IMB; Kigali, Rwanda), Boston Children’s Hospital (BCH; MA, USA), and other institutions, is based on a mattress containing 12 phase change material “candles” designed by PureTemp (Minneapolis, MN, USA) that melt to skin temperature and remain so for up to six hours. Once cooled down, the mattress can be cleaned and reused multiple times. It was specifically designed to complement skin-to-skin care (SSC) kangaroo mother care (KMC), either when it provides insufficient heat or if the mother needs to take a break.
To test the mattress, the researchers conducted a cluster-randomized stepped-wedge trial to assess its effect on euthermia and mortality, compared to standard of care in rural Rwandan hospitals. Ten district hospitals enrolled 464 unique infants who used the warmer 892 times. The results showed euthermia rates rose from 51% to 67%; among the encounters in which the warmer was used, only 11% remained hypothermic. Mortality rate among those who used the warmer (0.9%) were also significantly lower than among those who did not (2.8%). The study was published on April 16, 2021, in eClinicalMedicine.
“Infant hypothermia is a silent killer, but it's a modifiable risk factor, and this study shows that reducing it can have a large impact on survival and also likely on the long-term neurodevelopment of these babies,” said senior author Anne Hansen, MD, MPH, of BCH. “This is a good option for treatment in setting where incubators are not the right solution, whether it is because they are too expensive, require electricity, or require extensive training to correctly use and maintain.”
KMC was introduced in 1978 by Edgar Rey Sanabria, MD, in Bogotá (Colombia) as an alternative to incubators for low birth weight infants. KMC has four components: early, continuous, and prolonged SSC between the newborn and mother; exclusive breastfeeding; early discharge from the health facility; and close follow-up at home. It is thought to improve neonatal outcomes by maintaining infant temperature through SSC and by providing the benefits of breastfeeding, which are beneficial for all newborns, but may be especially advantageous for preterm infants.
Related Links:
Partners In Health/Inshuti Mu Buzima
Boston Children’s Hospital
PureTemp
Latest Patient Care News
- First-Of-Its-Kind Portable Germicidal Light Technology Disinfects High-Touch Clinical Surfaces in Seconds
- Surgical Capacity Optimization Solution Helps Hospitals Boost OR Utilization
- Game-Changing Innovation in Surgical Instrument Sterilization Significantly Improves OR Throughput
- Next Gen ICU Bed to Help Address Complex Critical Care Needs
- Groundbreaking AI-Powered UV-C Disinfection Technology Redefines Infection Control Landscape
- Clean Hospitals Can Reduce Antibiotic Resistance, Save Lives
- Smart Hospital Beds Improve Accuracy of Medical Diagnosis
- New Fast Endoscope Drying System Improves Productivity and Traceability
- World’s First Automated Endoscope Cleaner Fights Antimicrobial Resistance
- Portable High-Capacity Digital Stretcher Scales Provide Precision Weighing for Patients in ER
- Portable Clinical Scale with Remote Indicator Allows for Flexible Patient Weighing Use
- Innovative and Highly Customizable Medical Carts Offer Unlimited Configuration Possibilities
- Biomolecular Wound Healing Film Adheres to Sensitive Tissue and Releases Active Ingredients
- Wearable Health Tech Could Measure Gases Released From Skin to Monitor Metabolic Diseases
- Wearable Cardioverter Defibrillator System Protects Patients at Risk of Sudden Cardiac Arrest
- World's First AI-Ready Infrasound Stethoscope Listens to Bodily Sounds Not Audible to Human Ear